27
IQAN-XC21 Technical Overview
Appendix A
Instruction book, IQAN-XC21
Power driver - DOUT
CAN
Number of DOUT
low-side 8 (configuration may reduce number)
Maximum load
Single channel
DOUT ABCD Combined
DOUT EFGH Combined
300 mA
850 mA
850 mA
Leakage current in OFF state <200 uA
Protection over load, SCB, SCG
Diagnostics
Operational ON
Operational OFF
over load
open load
Number of CAN buses 1
CAN specification 2.0A and 2.0B
CAN bus speed 250 kbit
Protection SCB, SCG