UM1004 | MRO-00011 05/21 Rev.0 DCO-016875 20
18. Torque Anti-Rotation Sub (Y-63700-161-1) to Outer Housing (Y-63700-104-1) with 350 ft-lb [Joint B].
19. Apply Dow Corning 111 to TSP, thoroughly covering T-Seals (J-28460-36).
20. Slide TSP with T-Seals into Sealing Sub Body (Y-63700-140-1). Install Sealing Sub Assembly (J-28460-39) to Outer
Housing and torque to 350 ft-lb (Y-63700-104-1) [Joint A].
It is critical to apply ample thread lubricant per Table 6 to this joint to avoid galling as pre-compression is applied to
the elastomer section.
21. Install O-Rings onto Sealing Sub Assembly (J-28460-39) and install Thread Protectors.