EasyManua.ls Logo

Parker P1 Series - Page 58

Parker P1 Series
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannin Corporation
Hydraulic Pump and
Power Systems Division
Marysville, Ohio USA
Bulletin HY28-2665-02/SVC/EN
Medium Pressure Axial Piston Pumps
P1/PD Maintenance
58
PERFORMANCE SPECIFICATIONS
PUMP WITH LOAD SENSE COMPENSATOR
STEP
REFERENCE
CONDITION 060 075 100 140
1 Rated Speed (RPM) 1800 1800 1800 1800
4
Load sense output ow setting
at 50 ± 2 bar (725 ±30 psi)
60-63 lpm 77-79 lpm 103 - 105 lpm 145-147 lpm
5
Allowable ow variation from
50 to 260 ± 2 bar (725 to 3770 ± 30 psi)
56-66 lpm 73-83 lpm 99-109 lpm 136-156 lpm
TEST PROCEDURE
PUMP WITH LOAD SENSE COMPENSATOR
STEP
REFERENCE
CONDITION REQUIRED VALUE MEASURED VALUE
1 Set the pump speed to 1800 RPM 1800 rpm
2 Record input oil temperature 43-54 ° C (110 – 130 °F)
3A
Set output load prssure to 50 ± 2 bar
(725 ± 30 psi)
n/a n/a
3B
Adjust throttle valve and adjust differential setting
until pressure at pump outlet is 20 ± 2 bar
(290 ± 30 psi) higher than the load pressure gage
n/a n/a
4
Adjust throttle valve to required ow raqte. Adjust
output load presure valve if necessary to maintain
50 ± 2 bar (725 ± 30 psi)
See performance chart
5
Increase the output pressure to 260 ± 2 bar
(3770 ±30 psi). Verify that the ow remains within
specied limits.
See performance chart
6
Lock the load sense adjustment screw. Conrm
differential pressure at 20 ± 2 bar (290 ± 30 psi).
n/a n/a
7 Verify no external leaks No leakage permitted
060, 075, 100, 140 Pump Test Procedure