Page #9 background image
Bulletin HY13-1650-M1/USA
Piston Pump Service Procedure
P2 / P3 Series
Parker Hannifin Corporation
Hydraulic Pump/Motor Division
Greeneville, Tennessee US
9
Control is malfunctioning.
Clean, petroleum-based solvent
Vise with soft jaws
Air pressure source
Arbor press
Screw driver
Breaker bar
Torque wrench-(Nm) ft lbs: Range: 0-425 Nm
Adjustable crescent wrench
Fluid mineral oil ISO VG 32 @ 40
o
C
Clean corrosion resistant grease, oil or petroleum jelly.
Hex bits and Allen Keys (or T-handle).
Metric: 3mm, 5mm, 6mm, 8mm, 10mm, 12mm and 14mm
SAE: 1/8”, 5/32”, 3/16”, 3/8”, 1/2”, 9/16” and 5/8”
Sockets (deepwall)
Metric: 17mm, 19mm, 32mm or 36 mm and 38 mm
SAE: 9/16” and 1”
Internal snapring pliers: small and large
Box end wrench: 13mm (1/2”), 17mm deep offset
Pencil magnet
Loctite 242
CAUTION: Mixing greases that have different bases can be detrimental to bearing life.
Tools and Materials Required for Servicing
Troubleshooting Checklist
Trouble Cause Remedy
Clean orifices in control of contamination. Confirm
orifice and plugs are properly assembled.
If torque control pump, is saturation orifice in place.
Pump won’t
compensate

Other manuals for Parker P2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker P2 Series and is the answer not in the manual?

Parker P2 Series Specifications

General IconGeneral
BrandParker
ModelP2 Series
CategoryWater Pump
LanguageEnglish

Related product manuals