Chapter 2: Installing the PowerStation Selecting a Location
PA2 PowerStation User Guide 2-5
Class I, Division 2 Guidelines
If you purchased a Class I, Division 2-compliant PowerStation, it is suitable
for use in Class I, Division 2, Groups A, B, C, and D or non-hazardous
locations only. You must follow these guidelines in order to maintain a safe
operating environment.
When performing field wiring, always use copper wire with 60C or
60/75C insulation and a tightening torque of 7.0lbs/in (0.79 N-m).
The PA2 PowerStation is intended to use a branch circuit protection
rated 20 Amps or less.
Make sure that the PA2 PowerStation’s “ON/OFF” switch is secured in
the “ON” position using the supplied bracket.
WARNING!
Explosion Hazard!
Do not connect or disconnect cables unless the power has been
switched off, or the area is known to be non-hazardous. Keyboard,
mouse, and USB ports are for system setup and diagnostics only and
are not intended for permanent connection.
Class I, Division 2 approval requires nonincendive field wiring for
Class I, Groups A, B, C, and D hazardous locations only. With a
temperature code of T5.
Class I, Division 2 approval requires power switch restraints in
hazardous environments.
Substitution of components may impair suitability for Class I, Division
2.
Do not disconnect equipment unless power has been switched off or
the area is known to be non-hazardous.