EasyManua.ls Logo

Parker PowerStation PA2 Series - Electrical Specifications

Parker PowerStation PA2 Series
58 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Appendix A : PowerStation Specifications Electrical Specifications
PA2 PowerStation User Guide A -7
Electrical Specifications
The PA2 PowerStation’s power supply automatically detects the input
voltage level and adjusts accordingly. However, always use reliable
sources of power, and isolate all communication cables from AC power
lines to enhance noise immunity.
If possible, locate the PA2 PowerStation away from machinery that
produces intense electrical noise (arc welders, etc.). Otherwise, isolate the
input power to the PowerStation from the equipment generating electrical
noise.
The PA2 PowerStation’s electrical specifications appear in Table A-7.
Table A-7: Electrical Specifications Chart
Caution: Do not apply AC power to the unit or damage may occur.
Category All units
Input voltage PA200 & PA206:
12/24 VDC @ 18W
(Range: min 11 VDC, 28 VDC max)
PA208, PA210 & PA215:
24 VDC @ 22W
(Range: min 18 VDC, 28 VDC max)
Fuse Littlefuse Nano SMF Slow Blow Type fuse. The
part number is R454 002.
Heat
Dissipation
PA200:
4.5 watts maximum
PA206:
5.8 watts maximum
PA208:
7.8 watts maximum
PA210:
8 watts maximum
PA215:
25.5 watts maximum

Table of Contents