Parker PV Series - 12. Cables and connections; Cable 1 from CIP and LVDT (displacement transducer); Cable 2 from pressure sensor (compensator codes...UPM,...UPF,...UPQ)

Parker PV Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Parker Hannifin Manufacturing Germany GmbH & Co. KG
Pump & Motor Division Europe
Chemnitz, Germany
Electro hydraulic proportional controls version 45 for
axial piston pumps, PV series
Bulletin MSG30-3254-INST/UK
Installation and setup manual
12. Cables and connections
Cable 1 from CIP and LVDT (displacement transducer)
Cable 2 from pressure sensor (compensator codes ...UPM, …UPF, ...UPQ)
cable:3 x 0,5 mm², shielded, max. 50 m long
connector: according DIN 43 650, version AF, 4-pin
protection class IP 65 for voltages up to 250
V
Alternative: shielded cable with molded
connector; in dierent length and variations.
cable: 4 x 0,5 mm², shielded, max. 50 m long
connector: CIP: round type M12 x 1; 4-pin
LVDT: round type M12 x 1; 5-pin
angled version
protection class IP 65 for
voltages up to 250 V
CIP
PQ-module, control
Pin 6
+24 V
Teach-in
Pin 9
PQ-module, control
LVDT
cable 3 a/b: 3 x 0,5 mm², shielded, max. 50 m long
connector: according DIN 43 650, version AF, 4-PIN
protection class IP 65 for voltages up to 250V
cable: 4 x 0,5 mm², shielded, max. 50 m long
connector: CIP: round type M12 x 1; 4-pin
LVDT: round type M12 x 1; 5-pin
angled version
protection class IP 65 for voltages uop to 250 V
Notice: To protect the sensor, a cable strain
relief should be provided on the system side.