6 Technical Data:
Version Digital pressure gauge with ACT - MIN and MAX Display
bar graph display (33 segments) with peak and hold function
4 ½ digit LC display (15 mm) with back light illumination
Battery powered with low power electronic system.
Life time cycle 1.500 hrs (No back light function)
Pressure port stainless steel 1.4404
1/4 BSPP (ISO 1179-2) or
7/16 – 20 UNF (ISO 11926-2/3)
Input:
Ceramic sensor cell (relative) –1. . 16 bar
Strain gauge cell (absolute) 0. . 100/400/600 bar
Fluids and gases
Oil, water, air and oxygen
NBR sealed
Accuracy
Tolerance ± 0,5%FS (Full Scale)
Resolution
12 bit = 4.096 steps
MAX-MIN Memory
Scanning rate 10 msec.
Ambient conditions
Operating temperature
Fluid temperature
Storage temperature:
Rel. humidity:
Protection:
Vibration:
Shock:
-10. . 50 °C
-20. . +80°C
-20. . +60°C
< 85%
EN 60529 (IP 67)
IEC 60068-2-6, (5g)
IEC 60068-2-27 (25g)
Power supply
Battery 2 x1,5 VDC (LR6 –AA) Alkaline (Mignon)