1 General
The ServiceJunior digital pressure gauge measures and displays pressures and corresponding
MIN and MAX readings. The accuracy (tolerance) is given by ± 0,5% related to Full scale. (FS).
Running with a scanning rate of 10 msec (100 readings per second) pressure peaks are captured.
The MIN/MAX memory will be permanent updated.
1.1 Safety Hints / Product Selection
The proper function of the ServiceJunior according to these operating instructions is only guaranteed if
the specifications described in these operating instructions are observed.
This is especially true for the observation of the permissible upper limit of the effective range as well as
the temperature range.
The application of the selected product in areas not described in the specifications (improper use)
or the non-adherence to the instructions in the manual may lead to serious malfunctions which may even
cause damage or bodily injury. Especially the improper assembly of the pressure gauge and the
associated adapters may lead to the tearing off of the pressure gauge and/or to fluid leaks.
Please contact your Parker Hannifin Sales Office for Service, Repair and calibration.
1.2 Model Versions
Versions and scope of supply
Default setting “bar”
Pressure port 1/4 BSPP male
Deliveries includes Adapter M16x2
Default setting “PSI”
Pressure port 7/16-20 UNF male
Deliveries without Adapter
Range Part No. Range Part No.
-1…16,00 bar SCJN-016-01 -1…230,0 SCJR-0230-02
0…100,0 SCJN-100-01 0…1500 SCJR-1450-02
0…400,0 SCJN-400-01 0…5800 SCJR-5800-02
0…600,0 SCJN-600-01 0…8700 SCJR-8700-02