EasyManua.ls Logo

Parker SensoControl - Page 21

Parker SensoControl
21 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
page
19
of
21
Digital Pressure Gauge ServiceJunior
wireless
Range
bar
Display
bar
Display
PSI
Display
mbar
Display
kPa
Display
MPa
-
1…16
-
1,00...
16,00
-
14,5...200,0
-
999...16000
-
100...1600
-
0…
100
0...100,0
0...1500
-
0...10000
0...10,00
0…400
0...400,0
0...5800
-
0...4000 (x10)
0...40,00
0…600
0...600,0
0...8700
-
0...6000 (x10)
0...60,00
0…1000
0...1000
0...15000
-
-
0...100,0
R
ange (bar)
-
1…16
0…
100
0…400
0…600
0…1.000
Overload P
max
(bar)
40
200
800
1.200
1.500
Burst Pressure
(bar)
50
800
1.700
2.200
2.500
The
ServiceJunior
wireless
meets the guidelines of the European Community (EU).
It is confirmed that this product is appr
oved acc. to following standards:
This device complies with part 15
of t
he FC
C rules.
Op
erati
on is
subject to the
following two c
onditions:
(
1
) t
he de
vice may not
c
ause
harmful
interference
,
and (2) this device must accept any interf eren
ce
receiv
ed
, including
interference that may cause undesired operation.
This equipment has been tested and
found to comply with the limits for a
Class
B digital device, pursuant to part 15 of the
FCC Rules. These limits are
designed to provide reasonable
protection against harmful
interference in a
residential installation.
This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference
to radio communi
cations.
However, there is
no guarantee that interference will not occur
in a particular
installation. If this equipment does cause harmful interference to
radio or
television reception, which can be
determined by turning the equipment off
and
on, the user
is encouraged to try to correct
the interference by one or
more of the following measures:
-
Reorient or relocate the receiving antenna.
-
Increase the separation between the equipment and receiver.
-
Connect the equipment into an outlet on a
circuit diff
erent from that to which
the receiver is connected.
-
Consult the dealer or an experienced radio/TV technician for help.
Technical subject to change
Ju
ly
2009
DIN / EN 61000
-
6
-
2
DIN / EN 61000
-
6
-
3
Burst pressures related to tests without assembled adapters.
Exceeding the maximum ov
erload values (P
max
) may lead to
malfunctions and may even destroy the
ServiceJunior
wireless
.

Other manuals for Parker SensoControl

Related product manuals