4
Technical Specification
Seasoned Wood (less than 20% moisture content)
Anthracite or a manufactured briquette smokeless fuel which is
suitable for closed door appliances.
Mean Flue Gas Temperature
Mean Flue Gas Temperature
Flue Outlet Size (Top or Rear Option)
- Where leakage is greater than
5m³/hour/m²
- Ventilation normally required =
550mm² per kW output over 5kW
- Where leakage is less than or equal to
5m³/hour/m²
- Ventilation normally required =
550mm² per kW output
For further information on ventilation please refer to Building Regulations Document J or your installer.
This stove has been designed and assembled so that it may be used to burn wood logs in a Smoke Control Area.
Find out if you are in a Smoke Control Area by contacting your Local Authority.
The Derwent, Consort 4, Consort 5 and Compact 5 and Consort 5 Slimline have been fitted with a permanent stop
that prevents closure of the secondary air slider. Removal of this will lead to the appliance potentially causing smoke
emissions. Without the permanent stop in place the appliance is not an exempt appliance and so may leave the
householder liable for a fine up to £1000.