22
GB
chosen too long, especially if the
cable (8) is not hooked into the fas-
tening (4) .
Manual operation
The pump runs continuously in manual
operation.
Position the oat switch (3) directly
vertically in the fastening (4).
Switching on and off
1. Open the shut-off valve (9):
Use the shut-off valve to regulate the
amount of water that ows into the con-
nected water hose.
2. Fully immerse the pump.
3. Plug the mains plug into the power out-
let. The pump starts immediately.
4. To switch off, pull the mains plug out
of the power outlet. The pump switches
off.
If the water level is too low, the
oat switch will automatically
switch off the pump. The pump
does not switch off when you
close the stopcock (9). Switch off
the pump when you have nished
working.
Supervise the appliance while it is
in operation in order to be immedi-
ately aware if the automatic cut-out
operates or the pump runs dry, to
limit any damage to a minimum.
Maintenance/
Cleaning/ Storage
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to car-
ry out any work that is not
described in these instruc-
tions. Use only original parts.
There is a risk of injury!
Pull out the power plug before
every maintenance operation. There
is a risk of electrocution or of injury
from moving parts.
General cleaning instructions
• Clean the pump with clean water after
each use.
• Remove any uff and brous particles
that may have become trapped on and
under the pump housing (5) with a wa-
ter jet.
• Clean the oat switch (3) and the suc-
tion foot (6) of deposits with clear wa-
ter.
Cleaning the lter
(Fig A)
The pump has a removable lter in the
suction foot that protects it from contamina-
tion. Depending on the degree of contami-
nation of the water, it should be checked
occasionally and cleaned if necessary:
1. Unplug the mains plug.
2. Turn the lter cover (19) a ¼ turn clock-
wise.
3. Remove the lter cover (19).