DS 350 G Boom Control Troubleshooting- TMS/TTS870 / RT865 BXL
031-300-190-039 Rev. B 4/30/99
8
Rod side dump valve:
Relay K3 controls the rod side dump valve. The valve dumps the rod side pressure when the
controller is in neutral position and during the time the section stops while changing over to
another section.
Controller Relay K3
A101 x1/ 57
Extend on 0V
Retract on 0V
Neutral +24V
Retracted/ retract on +24V