DS 350 G Boom Control Troubleshooting- TMS/TTS870 / RT865 BXL
031-300-190-039 Rev. B 4/30/99
63
18.2 Additional Error Codes - System
Error code Description Solution
E 47 Processor can not locate analog
output circuit for center mid section
Analog output circuit defective. Replace
module.
Ribbon cable (DS 350G only) defective or
bad connection. Replace cable.
Decoder circuit defective. Replace decoder
module(DS 350G only).
E 60 DATA- EPROM is not plugged into
the correct socket or location is not
programmed correctly in the EPROM.
Refer to the trouble shooting manual and
identify the correct location for the data
eprom.
E70 No or wrong return signal from digital
input extension module to processor.
Digital input circuit defective. Replace
module.
Ribbon cable (DS 350G only) defective or
bad connection. Replace cable.
Decoder circuit defective. Replace decoder
module(DS 350G only).
Defective input circuit on main board. Call
authorized service personnel.
E80 / E98 No or wrong return signal from analog
output extension module (for inner
mid section) to processor.
Analog output circuit defective. Replace
module.
Ribbon cable (DS 350G only) defective or
bad connection. Replace cable.
Decoder circuit defective. Replace decoder
module(DS 350G only).
Defective input circuit on main board. Call
authorized service personnel.