DS350GM - BOOM CONTROL EXTENSION RT 865BXL 3
031-300-190-047 Rev0 02/17/1999
SERVICE AND MAINTENANCE
Daily maintenance of the load moment indicator consists of inspecting:
1. The electrical wiring connecting the various parts of the system.
If electrical wiring is damaged, it shall be replaced immediately.
2. If the insulation is worn on the length sensor cable or cable guides are damaged,
these parts shall be replaced.
3. Check the anti two-block limit switches for freedom of movement.
4. The cable reel shall be under tension to operate properly.
5. Check the pressure transducers at the hoist cylinder(s) and the connecting hoses for
oil leakage.
Other than correcting the problems identified in the Malfunctions Table and replacing
faulty mechanical parts and cables, non-expert personnel shall perform no other
repairs.