EasyManua.ls Logo

Payne PG8J - Page 14

Payne PG8J
52 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
TABLE 4—OPENING DIMENSIONS (IN.)
FURNACE
CASING
WIDTH
APPLICATION
PLENUM OPENING FLOOR OPENING
A B C D
14–3/16
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
12---11/16 21---5/8 13--- 5/16 22--- 1/4
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
12---9/16 19 13--- 3/16 19--- 5/8
Downflow applications on combustible flooring (KGASB sub-
base required)
11---13/16 19 13--- 7/16 20--- 5/8
Downflow Applications on Combustible Flooring with CD5 or
CK5 Coil Assembly or KCAKC coil box (KGASB subbase not
required)
12---5/16 19 13--- 5/16 20
17–1/2
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
16 21---5/8 16---5/8 22---1/4
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
15---7/8 19 16---1/2 19---5/8
Downflow applications on combustible flooring (KGASB sub-
base required)
15---1/8 19 16---3/4 20---5/8
Downflow Applications on Combustible Flooring with CD5 or
CK5 Coil Assembly or KCAKC coil box (KGASB subbase not
required)
15---1/2 19 16---1/2 20
21
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
19---1/2 21--- 5/8 20---1/8 22---1/4
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
19---3/8 19 20 19---5/8
Downflow applications on combustible flooring (KGASB sub-
base required)
18---5/8 19 20---1/4 20---5/8
Downflow Applications on Combustible Flooring with CD5 or
CK5 Coil Assembly or KCAKC coil box (KGASB subbase not
required)
19 19 20 20
24---1/2
Upflow Applications on Combustible or Noncombustible Floor-
ing (KGASB subbase not required)
23 21---1/8 23---5/8 22---1/4
Downflow Applications on Noncombustible Flooring (KGASB
subbase not required)
22---7/8 19 23---1/2 19---5/8
Downflow applications on Combustible flooring (KGASB sub-
base required)
22---1/8 19 23---3/4 20---5/8
Downflow Applications on Combustible Flooring with CD5 or
CK5 Coil Assembly or KCAKC coil box (KGASB subbase not
required)
22---1/2 19 23---1/2 20
PG8J/M

Other manuals for Payne PG8J

Related product manuals