443B101/443B102 27
Manual 19854 Rev. D
ECN 50523
Command: OFF?
Purpose: Returns the dc offset of the amplifier when in ICP long time time constant
mode.
Response: The module responds with the 6 character dc offset voltage.
Command String: XYCO2OFF?
Description: X— Rack number of the target module (Range: ASCII printable characters, 0
through 3)
Y— Slot number of the target module. (Range: ASCII printable characters, 0
through 7)
C02— Module type for the target. Only type “C02” (443B102) can accept this
command since the 443B101 does not have long time constant.
OFF?— Commands the module to return the dc offset.
Response String: XX.XXX
Description: This return indicates that the command was received by the card.
Example: Command String: “02C02OFF?”
Response String: “10.361”
The dc offset level of the 443B102 in rack 0, and slot 2 is set to 10.361 volts.