t~
. -
-·
600V
CAT
Ill
pollution level.
Altitude < 2000m.
Working environment temperature and humidity:
0-40°(
( <80%
RH,
<
l0
°C
not
considered).
Storage environment temperature and humidity:
-10-60°(
( < 70%
RH,
battery taken off).
• Temperature coefficient:
0.1
x accuracy/°(
(<l8
°C
or
>28°
()
.
• Measure the maximum allowable voltage between the
measurement end and the ground: 600V
DC
or
600V
AC
RMS
.
•
Fuse
protection:
mA
gear:
Tube
FF
600mN600V;
Gear A:
Fuse
FF
10A/600V
• Conversion rate: About 3 times/second
• Display: 6000 counts
LCD
display. Display unit symbols
automatically according
to
measurement function gear.
• Over range indication: The
LCD
displays
"01..'.
' .
• Battery low voltage indication: When battery voltage
is
lower
than normal operating voltage,
the"Cil"
will
display.
•
Input
polarity indication: It will display
•-
• automatically.
•
Poy.,er
supply: 4 x 1.
SV
AAA battery.
• Dimension: 150 mm(L)x75mm(W)x48mm(H).
• Weight: About 240g (including battery).
4.2 Precision indicators
Accuracy: ± ( %reading + characters), warranty
is
one year
since the date
of
delivery.
Basic
conditions: Ambient temperature
is
l8°C
to
28
°C, and
relative humidity is no greater than 80%.
4.2.1
DC
voltage
Range
Resolution
Accuracy
600mV O.lmV
6V
lmV
±(0.
5%
reading + 3 characters)
60V
lOmV
600V lOOmV
Input
impedance:
lOMn.
Max. input voltage: 600Vdc
or
600Vac
RMS
.
4.2.2
AC
voltage
Range
Resolution
Accuracy
6V
lmV
±(0.8% reading
+ 3 characters)
60V
lOmV
(<SOOHz)
600V lOOmV
± (1.5% reading
+ 10 characters)
(>=SOOHz)
Input
impedance:
lOMn
Max. input voltage: 600Vdc
or
600Vac
RMS
.
Frequency response: OHz-lOKHz true
RMS
-~=--
-.~-----.
-
--
-~
.. -
~
23
-----
-
-----
-
------
/
.-
:.