4.6.4. Continuity check
WARNING!
To avoid electric shock, never measure continuity on circuits or
wires that have voltage on them.
1. Set the range switch to the ))) position.
2. Insert the black lead plug into the COM socket and the red
test lead plug into the positive ))) socket.
3. Press the MODE button until “)))” appears in the display
4. Touch the test probe tips to the circuit or wire you wish to
check.
5. If the resistance is less than 35Ω, the audible signal will sound.
The display will also show the actual resistance in ohms.
-41-