Do you have a question about the PeakTech 1660 and is the answer not in the manual?
Temperature | -40°C to 1000°C |
---|---|
Diode | Yes |
Continuity test | Yes |
Auto range | Yes |
Data Hold | Yes |
Relative measurement | Yes |
Power Supply | 9V battery |
Category | Digital Multimeter |
DC Voltage | 600V |
AC Voltage | 600V |
DC Current | 10A |
AC Current | 10A |
Resistance | 60MΩ |
Capacitance | 100mF |
Frequency | 10MHz |
Safety Rating | CAT III 600V |
Essential safety rules for operating the meter to prevent injury and damage.
Explanation of caution symbols and double insulation for safe operation.
Note on using supplied safety test leads according to IEC/EN 61010-031:2008.
Steps for unpacking the digital clamp meter and checking included items.
Details on display type, polarity, overload, battery, power, and environmental limits.
Covers max input values, AC voltage, frequency, and AC current specifications.
Details active, apparent, and reactive power measurement ranges and accuracy.
Covers power factor, phase angle, and active energy measurement parameters.
Explains display symbols, indicators, buttons, and terminals on the instrument.
Explains additional symbols like negative, AC, MR, Hz, MEM, FUL, and H indicators.
Diagram showing the clamp meter with numbered labels for all components and controls.
Details the operation of HOLD, SAVE, SEL, and MAXMIN buttons for measurements.
Instructions on examining the instrument and test leads before taking measurements.
Explains how the transformer jaw picks up AC/DC current and its placement.
Procedure for measuring AC current and AC voltage simultaneously.
Procedures for measuring 3-phase power and phase angle in 4-wire and 3-wire modes.
Procedure for measuring AC voltage and frequency simultaneously.
Procedures for measuring apparent power, reactive power, and power factor.
Procedure for measuring AC voltage and frequency simultaneously.
Procedure for measuring active energy and time simultaneously.
Instructions for using the non-contact voltage detector to identify live conductors.
Explains True RMS and Average value measurement methods and their accuracy.
Step-by-step guide for automatically installing the PC software and drivers.
Procedure for manually installing PC software drivers via CD.
Step-by-step instructions for safely replacing the meter's 9V battery.
Information regarding battery disposal and regulations as per legal requirements.
Instructions for periodic cleaning and general maintenance of the instrument.
Information on proper disposal of old batteries and relevant regulations.