EasyManua.ls Logo

PeakTech 3430 - Measurement Ranges and Accuracy

PeakTech 3430
60 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
38
2.2 Ranges
DC Voltage
Range
Resolution
Accuracy
220 mV
10 μV
± 0,05% of rdg. + 3 dgt.
2,2 V
100 µV
22 V
1 mV
220 V
10 mV
1000 V
0,1 V
Overload protection: 1000 V DC/AC
rms
Input resistance: 9 MΩ
AC Voltage
Range
Resolution
Accuracy
220 mV
10 μV
± 0,8% of rdg. + 4 dgt.
2,2 V
100 µV
22 V
1 mV
220 V
10 mV
750 V
0,1 V
Overload protection: 750 V DC /AC
rms
Input resistance: 9 MΩ
Frequency range: 40 … 400 Hz
DC Current
Range
Resolution
Accuracy
220 μA
10 nA
± 0,8% of rdg. + 4 dgt.
2200 μA
0,1 μA
22 mA
1 μA
220 mA
10 μA
10 A
1 mA
Overload protection: 250 mA/1000 V
10 A/1000 V
max. input current: µA/mA-ranges: 250 mA
10- A-range: 10 A