Pedigo P-2010, P-2020, P-2030, P-2040, P-2050, P-2055 Blanket Warming Cabinets Operation and Care Manual
3
Hazardous
Voltage Present
Protective Earth
Ground Symbol
Medical Equipment classified by Underwriters
Laboratories with Respect to Electrical Shock,
Fire and Mechanical Hazards only, in Accordance
with UL 60601-1 and CAN/CSA C22.2 No. 601.1.
UL File No.
E201645
Grounding reliability can only be achieved when equipment is
connected to an equivalent receptacle marked “Hospital Grade.”
DANGER
ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.
POWER REQUIREMENTS - P-2010
120 V.A.C. — 50/60 Hz, 1 ph
600 Watts, 5.5 Amps
Safety Class I Equipment
NEMA 5-15P
15A - 125V Plug
Hospital Grade
POWER REQUIREMENTS - P-2020
120 V.A.C. — 50/60 Hz, 1 ph
700 Watts, 6.0 Amps
Safety Class I Equipment
NEMA 5-15P
15A - 125V Plug
Hospital Grade
POWER REQUIREMENTS - P-2030
120 V.A.C. — 50/60 Hz, 1 ph
1000 Watts, 8.0 Amps
Safety Class I Equipment
NEMA 5-15P
15A - 125V Plug
Hospital Grade
POWER REQUIREMENTS - P-2040
120 V.A.C. — 50/60 Hz, 1 ph
2000 Watts, 16.0 Amps
Safety Class I Equipment
NEMA 5-20P
20A - 125V Plug
Hospital Grade
POWER REQUIREMENTS - P-2055
120 V.A.C. — 50/60 Hz, 1 ph
1700 Watts, 14.2 Amps
Safety Class I Equipment
NEMA 5-20P
20A - 125V Plug
Hospital Grade
POWER REQUIREMENTS - P-2050
120 V.A.C. — 50/60 Hz, 1 ph
1600 Watts, 13.0 Amps
Safety Class I Equipment
NEMA 5-20P
20A - 125V Plug
Hospital Grade
DANGER
AT NO TIME SHOULD THE INTERIOR
OR EXTERIOR BE STEAM CLEANED,
HOSED DOWN, OR FLOODED WITH
WATER OR LIQUID SOLUTION OF
ANY KIND. DO NOT USE WATER JET
TO CLEAN.
SEVERE DAMAGE OR
ELECTRICAL HAZARD
COULD RESULT.
WARRANTY BECOMES VOID IF
APPLIANCE IS FLOODED
To prevent an electrical shock hazard between the appliance
and other appliances or metal parts in close vicinity, an
equalization-bonding stud is provided. An equalization
bonding lead must be connected to this stud and the
other appliances / metal parts to provide sufficient
protection against potential difference. The terminal is
marked with the following symbol.
ELECTRICAL INFORMATION
The power specifications are located on the unit identification nameplate. This nameplate is
permanently attached to the unit and must be located to verify power requirements.
PREPARATION
Before operating the cabinet, clean both the interior and exterior of the unit with a damp cloth and mild soap
solution. Rinse carefully. Wipe with an appropriate disinfectant. Clean and install the blanket support assembly.
Environmental conditions for operation: Maximum room ambient temperature of 89°F (32°C).