Model 2745, Wireless Door Controller Installation and Operation Manual
The Peelle Company Guide 224
www.peelledoor.com Page 4 April 2011
II. INTRODUCTION
The Peelle Wireless Door Controller simplifies the installation and commissioning of
freight elevator doors. The controller meets or exceeds the requirements outlined in
ASME A17.1 / CSA B44 Safety Code for Elevators and Escalators. The integrated
variable frequency drive with encoder feedback provides closed loop control for
significant improvement over traditional door operation. With preloaded parameters and
easy terminal connections, the New Peelle Wireless Door Controller is the easiest door
controller in the industry. The revolutionary Wireless Door Controller is located at each
landing door and car door (gate). Each controller learns and responds to its dedicated
door. Through wireless connectivity the landing door and car door controllers function
to operate the door and gate in sequence operation. The interface between the landing
door and car door set is accomplished using wireless technology which means that the
elevator controller interfaces to the car door controller only. Connections are made on
top of the car just like a passenger door controller. There is no machine room
equipment involved. All components are contained within the hoistway.
Features
• Wireless communication
between landing door and car door controllers
• Plug & Play components for the fastest installation times
• Self-learning control setup with encoder feedback
• Pre-adjusted parameters for most applications
• LCD display on control board with diagnostics
• VVVF closed loop drive for energy savings efficiency
• Integrated functional housing for fast installation
• Significant increase in door lifetime with smooth operation
• Operates 3-phase motors up to 0.75kW
How it works…
After installing the door and connecting the control system and components, door
operation in independent IND mode is available. Doors will open and close according to
commands on the on-board OPEN and CLOSE buttons. Using the on-board parameter
buttons, the controller is setup for either a LANDING DOOR (Ld) or a CAR DOOR (Cd).
Then a CHANNEL is selected for each line
of doors/gate (i.e. front, rear) followed by a
unique address for each LANDING DOOR controller. The controller is set to LEARN
(Lr) mode at which time the opening is automatically learned by the controller. Once
complete the operation can be set to Automatic AUTO mode and is ready to run.
Using a wireless connection between the controllers within each channel, commands to
and from the elevator controller are communicated in order to provide proper door and
gate sequence operation. Door zones and emergency unlocking devices are also
checked and confirmed using the wireless connection.