EasyManua.ls Logo

PEERLESS ECT SERIES - Piping Guide

PEERLESS ECT SERIES
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ItemNo.
21A
SERIESECand ECT
Part No.
EC-6008
EC-6008-1
EC-6008-2
EC-6008-3
EC-6O02
EC-6002°1
EC-6002-2
EC-6002-3
EC-6000
Description
LowerLeftSideJacketPanel
LowerLeft SideJacketPanel
LowerLeft SideJacketPanel
LowerLeft SideJacketPanel
RightSideJacketPanel
RightSideJacketPenet
RightSideJacketPanel
RightSideJacketPanel
FrontJacketPanel
5/18"-18x 1-3/4" CarriageBoltw/Nuts
SideClean-OutCoverPlate
RightTopJacketPanel
RightTopJacketPanel
RightTopJacketPanel
RightTopJacketPanel
LeftTopJacketPanel
LeftTopJacketPanel
LeftTop JacketPanel
LeftTop JacketPanel
BaseLiner
BaseLiner
BaseLiner
BaseLiner
EC/ECT-03 EC/ECT-06
X
X
22 X
X
23 X X
24 X X
25 X-1085 X X
26 EC-6005 X
EC-6005-1
EC-6005-2
EC-6005-3 X
27 EC-6004 X
EC-6004-1
EC-6004-2
EC-6004-3 X
28 EC-3000 X
EC-3000-1
EC-3000-2
EC-30O0-3 X
ModelNo.
EC/ECTo04 EC/ECT-05
X
X
X
X
X X
X X
X X
X
X
X
X
X
X
E - PIPING
DONOTPIPEBOILERUNTILAFTERJACKETISINSTALLED.
1- See Figures5 and 6 for suggestedpipingto the boiler.Also,seeHydronicsInstituteResidentialHydronicHeatingGuide2000.
2 - Makeupcoldwatersupplyconnectiontothe boiler.
3 - Installpressuregaugeortemperature-pressuregaugein tappingprovided.See Figure9.
4 - Pluga!l opentappingsin the boilerandfill withwater.Applyapproximatelythirty(30) poundspressure.Checkto makecertainthatalljoints
and fittingsarewater tight,
5 - Afteralljointsand connectionshavebeenprovenwatertight,removecold watersupplyandplugsfromall tappingsthat areto beused.See Figure
9 for tappinglocations.
6 - The returnpipingto the 1-1/4" NPT lowertappingonthe frontsectionmustbe installedin sucha mannerto assureproperclearanceof the oil
burnerand mountingplatewhenopeningandclosingthe burnermountingplate.Peerlesssuggestsusinga 1-1/4"90 degreestreetelbowat this
lowertappingin orderto positionthe returnpipingawayfromthe mountingplateassembly.
NOTE:IFTHISBOILERANDDISTRIBUTINGSYSTEMIS USEDiNCONJUNCTIONWITHA REFRIGERATIONSYSTEM,THECHILLEDMEDIUM
SHALLBEPIPEDIN PARALLELWITHTHEBOILERANDTHE PROPERVALVESAPPLIEDTO PREVENTTHECHILLEDMEDIUMFROM
ENTERINGTHE BOILER.WHENTHEBOILERIS CONNECTEDTOHEATINGCOILSLOCATEDINAIRHANDUNGUNITSWHERETHEY
MAYBE EXPOSEDTOREFRIGERATEDAIRCIRCULATION,THEBOILERPIPINGSYSTEMMUSTBE EQUIPPEDWITHFLOWCONTROL
VALVESOROTHERAUTOMATICMEANSTOPREVENTGRAVITYCIRCULATIONOFTHEBOILERWATERDURINGTHECOOLINGCYCLE.

Related product manuals