Questions and Answers

  • K
    keithmcintoshAug 1, 2025
    What to do if my Pego ECP200 BASE 4A Control Unit shows error code Ed?
    • W
      watsonbrittanyAug 1, 2025
      If your Pego Control Unit displays the 'Ed' error code, which indicates an open door alarm, first verify the status of the door switch. Then, inspect the door switch connections to ensure they are secure.
  • G
    Gregory ClaytonAug 5, 2025
    What does it mean when the temperature is flashing on my Pego ECP200 BASE 4A Control Unit display?
    • M
      Michael WalkerAug 5, 2025
      A flashing temperature display on your Pego Control Unit indicates a minimum or maximum temperature alarm. Ensure the compressor is functioning correctly or the sensor may not be reading the temperature properly, or the compressor start/stop control may not be working.
  • A
    alicia14Aug 9, 2025
    Why is my Pego ECP200 BASE 4A showing error code Ec?
    • K
      Kevin ParkerAug 9, 2025
      The 'Ec' error code on your Pego Control Unit means that the compressor protection has tripped, possibly due to thermal protection or a max pressure switch activation. Verify that the compressor is functioning correctly and check the compressor absorption.
  • L
    Leah DanielsAug 14, 2025
    What does error code E8 mean on my Pego Control Unit?
    • S
      Sara JonesAug 14, 2025
      Error code 'E8' on your Pego Control Unit indicates a 'man in cold room' alarm. To resolve this, reset the alarm input inside the cold room.
  • J
    John BrooksAug 18, 2025
    What to do if my Pego Control Unit displays error code E0?
    • E
      espinozajudithAug 18, 2025
      If your Pego Control Unit is showing error code 'E0', it indicates a problem with the cold room temperature sensor. Check that the cold room temperature sensor is working properly. If the problem persists, replace the sensor.
  • A
    Aaron GilesAug 22, 2025
    How to fix error E1 on Pego Control Unit?
    • K
      kelli64Aug 22, 2025
      If your Pego Control Unit displays error 'E1', it means the defrost sensor is not working correctly. Check that the defrost sensor is working properly. If the problem persists, replace the sensor.
  • G
    Gary LoganAug 27, 2025
    What to do if my Pego ECP200 BASE 4A Control Unit shows error E2?
    • D
      daniel41Aug 27, 2025
      If your Pego Control Unit is displaying error code 'E2', it indicates that an EEPROM memory alarm has been detected. To resolve this, switch the unit off and then back on.

Summary

Technical Characteristics

Electronics Board Specifications

Detailed technical specifications for the ECP200 BASE 4/4A electronics board, including power, climatic conditions, and output characteristics.

Parameter Programming

Control Panel and Keypad Overview

Description of the control panel layout, buttons, and LED indicators.

Setting and Displaying Set Points

Instructions on how to view and modify temperature set points for the system.

Level 1 User Programming

Guide for user-level parameter configuration and available variables.

Level 2 Installer Programming

Advanced parameter programming for installers, including variable lists.

Options

TeleNET Monitoring System

Configuration for TeleNET monitoring and supervision system using RS485.

Modbus-RTU Protocol Configuration

Enabling RS485 output for Modbus-RTU communication protocol.

Alarm Relay and RS485 Switching

Configuring jumpers for switching between auxiliary relay and RS485 output.

Troubleshooting

Alarm Codes and Solutions

List of alarm codes, possible causes, and troubleshooting solutions for system anomalies.

Appendices

Wiring Diagrams

Wiring diagrams for ECP200 BASE 4 and ECP200 BASE 4A models.

Pego ECP200 BASE 4A Specifications

General IconGeneral
BrandPego
ModelECP200 BASE 4A
CategoryControl Unit
LanguageEnglish