PEGO S.r.l.
Via Piacentina, 6/b - 45030 -
ROVIGO
Tel: 0425 762906 - Fax: 0425 762905
www.pego.it - e-mail: info@pego.it
DESCRIPTION
200MICROP01 is a magnetic door switch
compatible with all Pego electronics and
electronic panels with low voltage digital
input. The simplicity of installation and its
technology make it the ideal accessory for
cold room management.
MAIN FEATURES
• Contact closed when the magnet is near the
sensor (door closed).
• No calibration required.
• The cable exit side can be established during
installation, by turning the bottom by 180°.
MODELS
Magnetic door switch with
N.O. contact
DIMENSIONS
MOUNTING VARIATIONS
Electrical characteristics
-20T90 °C
humidity < 90% Rel. Hum. not
condensing
-20T90 °C
humidity < 90% Rel. Hum. not
condensing
Unsuitable
operating
environments
Environments with strong vibrations
or impacts; aggressive, polluted or
corrosive atmospheres, exposure to
direct solar radiation, explosive
atmospheres or flammable gas.
PG7, max cable diameter = 7mm
Right or left side entry, rotating the
bottom.
Fixed screw terminals for cables with
cross-sections from 0.2 to 1.5mm
2
Dimensional, insulation and mechanical characteristics
74x48x40mm (sensor)
44x15x8mm (magnet)
Plastic body in PC + ABS UL94 V-0
ASSEMBLY INSTRUCTIONS
Open the door switch by unscrewing the two
screws on the back of the sensor to access the
board. Pass the cable through the PG and
connect the two wires to the terminal.
Close the sensor taking care to position the
bottom so as to have the cable outlet on the
desired side and tighten the two screws on the
back.
The door switch can be fixed to the wall using
the long screws provided. The magnet is
equipped with a double-sided adhesive, but it is
advisable to fix it to the door using also screws. It
is important that the door switch and the
magnet do not come into direct contact when
the door is closed; this to avoid shocks that could
damage them over time.
NB: The distance (D) between the magnet and
the sensor must be between 4mm and 7mm.
It is advisable to mount the door switch as high
as possible; follow the examples below.
PROBLEMS AND SOLUTIONS
• The contact is closed when the
magnet is near the sensor (door
closed). Invert the operating
logic of the electronic control
input to which it is connected.
When the door
is closed the
plant does not
restart
• Excessive distance between the
sensor and the magnet.
• Check the electrical
connections.
INSTALLATION EXAMPLES
1 = door side
2 = above the door
GENERAL INFORMATION
PEGO S.r.l. does not accept responsibility for any loss of data or information, costs of goods or
substitute services, damages to objects, persons or animals, lost sales or profits, interruption of
activities, any direct, indirect, accidental, property, insured, punitive, special or consequential damage
caused in any way, be it contractual, extra-contractual or due to negligence or other responsibility
resulting from the use of the product or its installation. The guarantee automatically becomes invalid
in the case of poor functioning due to tampering, impact or inadequate installation. It is mandatory to
observe all instructions in this manual and the operating conditions of the device. PEGO S.r.l. does not
accept responsibility for any inaccuracies which may be present in this manual in the case that these
are due to printing or transcription errors and reserves the right to make modifications to its products
which it deems necessary or appropriate, without prejudicing the products essential characteristics.