Performance Data Sheet
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed below. The concentration of
the indicated substances in water leaving the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specied in NSF/ANSI 58. Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system. Systems certied for cyst reduction may be used
on disinfected water that may contain lterable cysts.
This system has been tested for the treatment of water containing pentavalent arsenic (also known as AS(V), As +5, or
arsenate) at concentrations of </= 300 ppb. This system reduces pentavalent arsenic, but may not reduce other forms of
arsenic. This system is to be used on water supplies containing a detectable free chlorine residual at the system outlet or
on water supplies that have been demonstrated to contain only pentavalent arsenic. Treatment with chloramine (combined
chlorine) is not sufcient to ensure complete conversion of trivalent arsenic to pentavalent arsenic. Please see the Arsenic
Facts section of the Performance Data Sheet for further information.
Testing was performed under standard laboratory conditions, actual performance may vary. Incoming water must be free
of potential membrane foulants such as Iron, Hydrogen Sulde and Manganese. Efciency rating means the percentage
of the influent water to the system that is available to the user as reverse osmosis treated water under operating conditions
that approximate typical daily usage.Recovery rating means the percentage of the influent water to the membrane portion
of the system that is available to the user as reverse osmosis treated water when the system is operated without a storage
tank or when the storage tank is bypassed.
This reverse osmosis system contains a replaceable component critical to the efciency of the system. Replacement of the
reverse osmosis component should be with one of identical specications, as dened by the manufacturer, to ensure the
same efciency and contaminant reduction performance. Feed water conditions may affect replacement intervals.
System Performance
System Maintenance
Model Number: PRO-RO Avg Daily Production Rate: 67.76 L/d (17.9 gpd)
Avg. Recovery: 30.7% Avg Efciency: 17.8%
Temperature: 4
℃
-38
℃
(40
℉
-100
℉
) Pressure: 2.81-5.62 kg/cm
2
(40-80 psi)
Influent
Challenge
Concentration
Maximum
Allowable
Concentration
Actual
Minimum %
Reduction
Average
Percent
Reduction
Arsenic (pentavalent) 50 ppb 10 ppb 98.1 99.0
Barium 10.0mg/L
±
10% 2.0 mg/L 95.0 98.8
Cadmium 0.03 mg/L
±
10% 0.005 mg/L 94.0 98.3
Chromium6 (Hexavalent) 0.3 mg/L
±
10% 0.1 mg/L 95.5 98.3
Chromium 3 (Trivalent) 0.3 mg/L
±
10% 0.1 mg/L 98.4 99.0
Copper 3.0 mg/L
±
10% 1.3 mg/L 95.0 98.4
Cysts Min 50,000/mL 110 counts/mL >99.99 >99.99
Fluoride 8.0 mL
±
10% 1.5 mL 87.0 93.8
Lead 0.15 mL
±
25% 0.010 mL 90.4 96.8
Radium 226/228 25 pCi/L
±
10% 5 pCi/L 95.0 98.8
Selenium 0.10 mg/L
±
10% 0.05 mg/L 94.4 97.9
Turbidity 11
±
1NTU 0.5 NTU 96.4 98.7
TDS (Total Dissolved Solids) 740mL 187 mL 86.6 93.1
Part Number Description Replacement Interval
104863 TF50, 4 stage cartridge 12 months
104851 5th stage inline post lter 6-12 months
.07
PELICAN PRO-RO 6 Instruction Manual