EasyManua.ls Logo

Pelpro PP70 - Troubleshooting; Power Related

Pelpro PP70
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PelPro Pellet Stove • 7103-171C • 11/1/18
pelprostoves.com
29
Troubleshooting
Troubleshooting
Troubleshooting
Pro Tip
Check passages to assure
they are clear of ash and
obstructions. Poor airow
leads to poor performance of
your Stove.
Troubleshooting your Stove
Visit pelprostoves.com or scan the code:
A
1
Zone
1
Zone
2
Zone
2
Zone
Power Related
In the event of a power outage:
If using a generator, PelPro recommends a steady state
generator for best Stove performance.
This Stove needs 110v to run properly. This Stove has
not been tested for use with a third party battery backup.
A
Stove plugged in but no response
Unplug your Stove
Check your home’s circuit breaker
Reset snap disc (located between drop tube and hopper
(Zone 2)
Visually inspect wires, blowers and power cord for
breaks or wear to nd cause of possible short circuit
(Zone 2)
Component (i.e. blower) fails to start or fails to turn o󰀨
Unplug your Stove
Check all connections and power plugs are secure
Visually inspect wires, blowers and power cord to nd
cause of possible short circuit