PelPro Cast Iron Pellet Stove
Please read this entire manual before installation and use of this pellet fuel-burning room heater, and save for future refer-
ence. Failure to follow these instructions could result in property damage, bodily injury or even death. Contact local building or
re ofcials about restrictions and installation inspection requirements in your area.
Note: To obtain a French translation of this manual, please contact your dealer or visit www.pelprostoves.com. Pour obtenir
une traduction francaise de ce manuel, s’il vous plait contracter votre revendeur ou visitez www.pelprostoves.com
WARNING!

Other manuals for Pelpro PPC90

Questions and Answers

  • J
    Jeremy RiddleSep 22, 2025
    What does Error Number 3 The ambient probe senses an abnormal temperature mean on my Pelpro Stove?
    • T
      Travis LynchSep 22, 2025
      If your Pelpro Stove displays 'Error Number 3 The ambient probe senses an abnormal temperature', this indicates that the ambient temperature is either above or below the acceptable range, there may be an ambient probe failure, or the probe may not be plugged in or a component has failed. Plug the probe into the board. Replace the component.
  • M
    Mrs. Sarah YatesAug 25, 2025
    What to do if my Pelpro Pellet stove will not light?
    • K
      Katie PriceAug 25, 2025
      If your Pelpro Pellet stove won't light, you can try the following: * Ensure the firepot holes are clean. * Verify the igniter is getting hot (glowing orange). * Inspect the stove body. * Make sure there is fuel in the hopper and the lid is securely closed. * Check that the vacuum switch is clear and connected. * Confirm all exhaust blower connections are secure. * Ensure the feed assembly and motor are free of debris. * Confirm the exhaust path is clean.
  • M
    Matthew ThomasAug 25, 2025
    What to do if pellets remain in the hopper of my Pelpro PPC90 Stove?
    • K
      Kayla WilsonAug 26, 2025
      If pellets remain in the hopper, empty any pellets and vacuum any remaining pellets or debris from the hopper.
  • H
    Haley FreemanAug 26, 2025
    What to do if there is debris in the convection blower of my Pelpro PPC90?
    • E
      Ethan BrownAug 26, 2025
      If you find debris in the convection blower of your Pelpro Stove, remove the right side panel to access and remove the convection blower. Then, vacuum any debris from the fan blades and blower housing.
  • C
    Cynthia GallagherSep 23, 2025
    Why is there black soot on the outside of my house from my Pelpro Pellet stove?
    • M
      Mr. James Graves DDSSep 23, 2025
      Black soot on the outside of your house from your Pelpro Pellet stove could be due to a dirty exhaust path. Make sure the exhaust path is clean and clear. You might also need to adjust the air/fuel ratio using the trim adjustment dial. Also, ensure the termination cap has at least 18” clearance to reduce soot blow-back.
  • A
    alyssa87Dec 1, 2025
    What does Error Number 1 mean on my Pelpro Pellet stove?
    • A
      Amy MorganDec 1, 2025
      Error Number 1 on your Pelpro Pellet stove indicates several potential issues: * The hopper might be empty. * There could be a jam in the feed tube. * There may be obstructions in the venting or firebox. * The exhaust blower might not be running. * The hopper lid may be open. * The exhaust probe might not be recognizing the hot exhaust temperature. * The exhaust probe might not be attached to the outlet. * The exhaust path might be dirty. To resolve this, fill the hopper, inspect the feed tube for jams, inspect the venting and firebox for obstructions and clean if necessary, inspect the exhaust blower to make sure it runs, or close the hopper lid. Inspect and clean the exhaust outlet, firebox, firepot, and behind the baffles. Inspect the exhaust probe to see if it is secu...
  • A
    Amanda ClarkSep 12, 2025
    What does Error Number 5 mean on my Pelpro Pellet stove?
    • C
      Carrie KentSep 12, 2025
      Error Number 5 on your Pelpro Pellet stove indicates that the digital display is not communicating correctly with the stove control board. Inspect the cable for breaks or cuts and check the connection between the digital control and the control board. If that doesn't work, replace the component.
  • Z
    zrobinsonSep 12, 2025
    Why is there black soot on the outside of my house from my Pelpro PPC90?
    • L
      landersonSep 12, 2025
      If you're seeing black soot on the outside of your house from your Pelpro Stove, make sure the exhaust path is clean and clear. You may also need to adjust the air/fuel ratio using the trim adjustment dial. Also, ensure the termination cap has at least 18” clearance to reduce the effects of soot blow-back on your home.
  • B
    Brian CunninghamSep 4, 2025
    What does Error Number 3 mean on my Pelpro Pellet stove?
    • R
      rachaelstewartSep 4, 2025
      Error Number 3 on your Pelpro Pellet stove indicates that the ambient temperature is either above or below the acceptable range, or there is an ambient probe failure. It could also mean the probe is not plugged in. To solve this, try plugging the probe into the board. If that doesn't work, you may need to replace the component.
  • A
    Alex GonzalezSep 2, 2025
    What does Error Number 4 mean on my Pelpro Pellet stove?
    • B
      brownanthonySep 2, 2025
      Error Number 4 on your Pelpro Pellet stove, indicates a missed ignition. This can happen due to: * Lack of fuel (hopper empty). * A jam in the feed. * The feed not turning. * A disconnected or failed feed motor. * A dirty firepot. * Issues with the igniter (no power or failed). * Debris in the igniter chamber. To resolve this, fill the hopper, inspect and clear any jams in the feed tube, inspect the feed motor circuit, clean the firepot, check the igniter leads, and clean any debris from the igniter chamber.

Summary

Safety First!

Safety Alert Key

Defines safety alert symbols (DANGER, WARNING, CAUTION, Notice, Pro Tip) for hazard communication.

Fire Risk Notice

Details actions that void warranty and increase fire risk.

Hot Surfaces Hazard

Warns about extreme heat from surfaces and glass, and precautions for children.

Getting Started

Required Tools and Safety Gear

Lists essential tools, supplies, and safety equipment for installation and maintenance.

Installing Your Stove

Pellet Venting Requirements

Explains the critical aspects of pellet vent pipe configuration for safe operation.

Vent Termination Clearances

Details specific clearance requirements for the vent termination point.

Venting Installation Guide

Provides instructions for installing the stove's exhaust venting system.

Venting Calculations and Guidelines

Details rules for horizontal/vertical vent runs, elbows, and pipe lengths.

Using Your Stove

First-Time Startup Procedure

Guides users through the initial ignition sequence and expected operations.

Priming the Stove from Empty Hopper

Detailed steps to initiate fuel feed when the hopper is empty.

Maintaining Your Stove

Cleaning and Maintenance Overview

Highlights the importance of regular cleaning for stove performance.

Troubleshooting

Power Related Issues

Addresses problems related to power supply and electrical components.

Blockage and Airflow Problems

Diagnoses issues caused by soot, ash, or other obstructions.

Alarm Codes and Solutions

Explains specific error codes and their corresponding corrective actions.

PelPro Limited Warranty

Pelpro PPC90 Specifications

General IconGeneral
TypePellet Stove
BTU Output90, 000 BTU
Fuel TypeWood Pellets
IgnitionAutomatic
BlowerVariable Speed

Related product manuals