PelPro Cast Pellet Stove • 7093-600 • 07/13/16 pelprostoves.com24
Troubleshooting
Troubleshooting
Blockage Related
Fire starts but goes out
Conrm rebox is clean and clear (Zone 1)
- Ensure repot holes are clear
Inspect stove body (Zone 2)
- Conrm exhaust probe is connected
- Inspect and clean the exhaust outlet
Conrm exhaust path is clean and clear (Zone 3)
Starts and stops frequently in automatic mode
Determine if your room is experiencing varying temperatures due to repeated opening/
closing of doors or windows—correct if necessary
Examine stove body (Zone 2)
- Inspect ambient probe and conrm that at least 2” is exposed outside of stove
body
Slow or smoky start-up and/or lazy ame
Conrm exhaust path is clean and clear; clean your repot and behind your bafes
inside your rebox (Zone 3)
Examine stove body (Zone 2)
- Align igniter so it is properly placed and centered
- Review fuel quality (see Pellet Fuel
information on page 5)