PelPro Cast Pellet Stove • 7093-600 • 07/13/16pelprostoves.com 23
Troubleshooting
Troubleshooting
Blockage Related
Black soot on outside of house
• Conrm exhaust path is clean and clear (Zone 3)
- Adjust air/fuel ratio using trim adjustment dial
(See page 17 for trim adjustment instructions)
• Ensure termination cap has at least 18” clearance
to reduce the effects of soot blow-back on home
exterior (ie. siding)—if not able, refer to page 10
for alternate installation options
1
Zone
1
Zone
2
Zone
2
Zone
3
Zone
3
Zone
Rumbling/whistling noise during operation
• Conrm exhaust path is clean and clear (Zone 3)
- Adjust air/fuel ratio using trim adjustment dial (See page 17 for trim adjustment
instructions)
Stove will not light
• Conrm repot holes are clean and clear (Zone 1)
- Ignitor is getting hot (glows orange)
• Inspect stove body (Zone 2)
- Conrm fuel is in hopper, close lid securely
- Remove right side panel to access and conrm vacuum switch is clear and
connected at both ends
- Conrm all exhaust blower connections secure
- Conrm the feed assembly and motor are clean and clear of debris
• Conrm exhaust path is clean and clear (Zone 3)