PelPro Cast Pellet Stove • 7093-600 • 07/13/16pelprostoves.com 7
Installing Your Stove
Installing Your Stove
REQUIRED:
Use only 3” or 4” type “L” or “PL” pellet pipe.
CAUTION
Do not connect to any air distribution duct or system
Do not install a ue damper in the exhaust venting system of this
stove
Do not connect this stove to a chimney ue serving another
appliance
The structural integrity of the manufactured home oor, wall and
ceiling/roof must be maintained
C
C
Installation Video
Visit pelprostoves.com or scan this code:
Pro Tip
This unit can be installed with a 3 to 6 inch (76-152mm) Top Vent Offset Adapter Kit. The 3
to 6 inch (76-152mm) Top Vent Offset Adapter are tested to use 24 gauge single wall ue
connector or Listed double wall ue connector to Class A Listed metal chimneys, or masonry
chimneys meeting International Conference of Building Ofcials (ICBO) standards for solid
fuel appliances.
Getting Ready (Continued)
Pellet Venting
Adding bends in the exhaust path restricts air ow,
reduces performance and provides a collection point
for ash deposits requiring more frequent cleaning.