EasyManua.ls Logo

Pelpro PPC90 - Venting System Maintenance

Pelpro PPC90
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PelPro Cast Pellet Stove • 7093-600 • 07/13/16pelprostoves.com 21
Maintaining Your Stove
Electrical Components
Identify and remove any debris
Verify all connections are secure
Exhaust Blower
Remove right side panel to access and remove
exhaust blower
Vacuum any debris from the fan blades and blower
housing
Maintaining Your Stove
Zone 3 - Venting
Termination Cap
Remove termination cap
Brush out to remove dust and hard buildup
Vent Components
Soot, creosote, and y ash will collect in the
exhaust venting system and restrict the ow
of the ue gases. This build up will occur more
quickly in horizontal sections and elbows.
Use the appropriate sized chimney brush to
remove ash and buildup from the venting
Outside Air Kit
Ensure there are no obstructions in the outside
air kit cap
Having Trouble?
Visit the Troubleshooting section
of this manual.
1
Zone
1
Zone
2
Zone
2
Zone
3
Zone
3
Zone
Caution!
When wood pellets are burned at a low temperature, they produces organic vapors which combine with moisture
to form creosote vapors.
Creosote vapors condense in the relatively cool chimney ue of a newly-started or a low-temperature re. As a
result, creosote residue accumulates on the ue lining. When more heat is called for, this residue can be ignited,
which creates an extremely hot re in the chimney ue; this may damage the chimney or even destroy your home.
Your chimney should be inspected once every few months during the heating season to determine if a creosote
or soot buildup has occurred. If creosote or soot has accumulated, it should be removed to reduce the risk of
a chimney re.