PelPro Cast Pellet Stove • 7093-600 • 07/13/16 pelprostoves.com22
Troubleshooting
Troubleshooting
Power Related
In the event of a power outage:
If using a generator, Pelpro recommends
a steady state generator for best stove
performance.
This stove needs 110v to run properly. This stove
has not been tested for use with a third party
battery backup.
Stove plugged in but no response
Check your home’s circuit breaker
Reset snap disc (located between drop tube and
hopper (Zone 2)
Visually inspect wires, blowers and power cord
for breaks or wear to nd cause of possible short
circuit (Zone 2)
Component (i.e. blower) fails to start or fails to
turn off
Check all connections and power plugs are secure
Visually inspect wires, blowers and power cord to
nd cause of possible short circuit
Pro Tip
Check passages to assure
they are clear of ash and
obstructions. Poor airow
leads to poor performance
of your stove.