Instruction Manual
Installer: Affix these instructions adjacent to the boiler
Homeowner: Retain these instructions for future reference
PCC 34-H
Condensing Direct Vent Gas Boiler
116,000 BTU INPUT
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may
result, causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or
any other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance
• Do not touch any electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
•If you cannot reach your gas supplier, call the fire department
-Installation and service be performed by a qualified installer, service agency or the gas
supplier.
-Use of a properly calibrated electronic combustion analyzer MUST be used to install and/or
service this appliance.
Approved in accordance with:
ANSI Z21.13b-2010 / CSA 4.9b (2010) Low Pressure Boiler
Manufactured/Distributed by: Granby Furnaces Inc.
12118 Hwy 209, Parrsboro, NS, Canada

Questions and Answers

  • T
    Taylor BraunAug 18, 2025
    What to do if PENSOTTI Boiler has flame detection malfunction?
    • N
      Nathan MurphyAug 18, 2025
      If your PENSOTTI Boiler's flame detection is malfunctioning, the issue might be with the ionization electrode. Try cleaning it, or consider replacing it. Alternatively, the ionization electrode cable could be faulty and need replacement, or the printed circuit board could be malfunctioning, requiring replacement.
  • V
    Valerie CastroAug 21, 2025
    What to do if safety thermostat tripped on PENSOTTI PCC 34-H Boiler?
    • E
      Emily BensonAug 21, 2025
      If the safety thermostat on your PENSOTTI Boiler trips at 203 °F (95 °C), it could be due to a thermostat malfunction or being out of calibration, requiring a replacement. Alternatively, the thermostat cable might be disconnected, so you should check the wiring.
  • M
    Mark HoldenAug 25, 2025
    Why is the heating sensor not working on my PENSOTTI Boiler?
    • M
      mark61Aug 25, 2025
      If the heating sensor in your PENSOTTI Boiler is malfunctioning, it might be due to the sensor itself being out of calibration (resistance value 10 kOhms at 77 °F / 25 °C), in which case you should replace it. Another possibility is that the sensor cable is disconnected or wet; check the electrical connection.
  • R
    Robert GrossAug 28, 2025
    What causes the fluesafety thermofuse to fail in PENSOTTI Boiler?
    • R
      Raymond AnthonyAug 28, 2025
      If the flue safety thermofuse in your PENSOTTI Boiler is experiencing issues, it could be due to a broken thermofuse, which requires replacement. Alternatively, the thermofuse cable might be disconnected; in this case, check the electrical connection. A thermofuse lockout, caused by high flue temperature, may also occur, so restart and check the thermofuse.
  • K
    Kathleen WhiteheadAug 31, 2025
    What to do if PENSOTTI Boiler shows no water in the system?
    • B
      bartlettjamesSep 1, 2025
      If your PENSOTTI Boiler indicates no water in the system, it could be due to insufficient water pressure (stopping at 0.3 bar). In this case, fill the system. Another potential cause is a disconnected water pressure switch cable, so check the wiring. Additionally, the water pressure switch itself might be malfunctioning, requiring replacement.
  • D
    Donna TuckerSep 4, 2025
    Why is D.H.W storage cylinder sensor not working on PENSOTTI Boiler?
    • M
      Melissa FaulknerSep 4, 2025
      If the D.H.W storage cylinder sensor in your PENSOTTI Boiler is malfunctioning or incorrect (resistance value 10 kOhms at 77 °F / 25 °C), consider replacing it. Alternatively, the sensor cable might be disconnected or wet; check the electrical connection.
  • A
    Amy ValdezSep 7, 2025
    How to fix a burnt fan on PENSOTTI Boiler?
    • L
      Laura HunterSep 7, 2025
      If the fan in your PENSOTTI Boiler is not working, it could be due to a burnt fan, which requires replacement.
  • L
    Leon LawrenceSep 12, 2025
    Why does my PENSOTTI PCC 34-H Boiler need parameter programming?
    • M
      Mark PerkinsSep 12, 2025
      If your PENSOTTI Boiler is requesting parameter programming, it is likely due to a loss of microprocessor memory, which requires you to reprogram the parameters.
  • P
    Philip EvansNov 14, 2025
    How to fix no flame and tripped air pressure switch on PENSOTTI PCC 34-H Boiler?
    • R
      reidsheilaNov 14, 2025
      If the PENSOTTI Boiler shows no flame and the air pressure switch has tripped, and there's no ignition, first check the mains supply for gas. If that's not the issue, the problem could be a malfunctioning gas valve, in which case you should replace it. Alternatively, the mechanical minimum adjustment or slow ignition adjustment on the gas valve may be set too low; try regulating these. For LPG boilers, verify that the gas valve inlet pressure isn't too high by checking the maximum pressure setting. Also, inspect the condensate disposal system for blockages and empty the condensate trap, if needed. If the problem persists and there is ignition, check if the power supply live and neutral wires are inverted and connect them correctly. The issue might also be a faulty ionization electrode, whi...

PENSOTTI PCC 34-H Specifications

General IconGeneral
BrandPENSOTTI
ModelPCC 34-H
CategoryBoiler
LanguageEnglish