CONTENTS
Instruction Manual
Installer: Affix these instructions adjacent to the boiler
Homeowner: Retain these instructions for future reference
PCH
34B-H
Condensing Direct Vent Gas Boiler
116,000 BTU INPUT
WARNING
If the information in these instructions is not followed exactly, a fire or explosion may
result, causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or
any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance
Do not touch any electrical switch; do not use any phone in your building
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
•If you cannot reach your gas supplier, call the fire department
-Installation and service be performed by a qualified installer, service agency or the gas
supplier.
-Use of a properly calibrated electronic combustion analyzer MUST be used to install and/or
service this appliance.
Approved in accordance with:
ANSI Z21.13b-2010 / CSA 4.9b (2010) Low Pressure Boiler
Manufactured/Distributed by : Granby Furnaces Inc.
12118 Hwy 209, Parrsboro, NS, Canada

Questions and Answers

  • M
    Mr. Andrew GoldenAug 17, 2025
    What to do if PENSOTTI PCH 34B-H has flame detection malfunction?
    • L
      Lee WoodsAug 17, 2025
      If your PENSOTTI Boiler's flame detection is malfunctioning, the issue might be with the ionization electrode. Try cleaning it, or consider replacing it. Alternatively, the ionization electrode cable could be faulty and need replacement, or the printed circuit board could be malfunctioning, requiring replacement.
  • Y
    yreedAug 20, 2025
    What to do if safety thermostat tripped on PENSOTTI Boiler?
    • E
      emendozaAug 21, 2025
      If the safety thermostat on your PENSOTTI Boiler trips at 203 °F (95 °C), it could be due to a thermostat malfunction or being out of calibration, requiring a replacement. Alternatively, the thermostat cable might be disconnected, so you should check the wiring.
  • C
    Colin BennettAug 25, 2025
    Why is the heating sensor not working on my PENSOTTI PCH 34B-H Boiler?
    • D
      Daniel NelsonAug 25, 2025
      If the heating sensor in your PENSOTTI Boiler is malfunctioning, it might be due to the sensor itself being out of calibration (resistance value 10 kOhms at 77 °F / 25 °C), in which case you should replace it. Another possibility is that the sensor cable is disconnected or wet; check the electrical connection.
  • N
    Nicole MeyerAug 27, 2025
    What causes the fluesafety thermofuse to fail in PENSOTTI Boiler?
    • J
      Judy PittsAug 27, 2025
      If the flue safety thermofuse in your PENSOTTI Boiler is experiencing issues, it could be due to a broken thermofuse, which requires replacement. Alternatively, the thermofuse cable might be disconnected; in this case, check the electrical connection. A thermofuse lockout, caused by high flue temperature, may also occur, so restart and check the thermofuse.
  • K
    kelleymatthewAug 30, 2025
    What to do if PENSOTTI PCH 34B-H shows no water in the system?
    • J
      Jennifer AveryAug 30, 2025
      If your PENSOTTI Boiler indicates no water in the system, it could be due to insufficient water pressure (stopping at 0.3 bar). In this case, fill the system. Another potential cause is a disconnected water pressure switch cable, so check the wiring. Additionally, the water pressure switch itself might be malfunctioning, requiring replacement.
  • M
    Mr. Christopher MartinezSep 2, 2025
    Why is D.H.W storage cylinder sensor not working on PENSOTTI Boiler?
    • C
      Courtney Gray DDSSep 2, 2025
      If the D.H.W storage cylinder sensor in your PENSOTTI Boiler is malfunctioning or incorrect (resistance value 10 kOhms at 77 °F / 25 °C), consider replacing it. Alternatively, the sensor cable might be disconnected or wet; check the electrical connection.
  • S
    stanley13Sep 6, 2025
    How to fix a burnt fan on PENSOTTI Boiler?
    • P
      Phillip PhillipsSep 6, 2025
      If the fan in your PENSOTTI Boiler is not working, it could be due to a burnt fan, which requires replacement.
  • N
    Nancy HigginsSep 9, 2025
    Why does my PENSOTTI Boiler need parameter programming?
    • L
      Lisa LyonsSep 9, 2025
      If your PENSOTTI Boiler is requesting parameter programming, it is likely due to a loss of microprocessor memory, which requires you to reprogram the parameters.
  • A
    Amanda KimNov 13, 2025
    How to fix no flame and tripped air pressure switch on PENSOTTI Boiler?
    • E
      Emily JonesNov 13, 2025
      If the PENSOTTI Boiler shows no flame and the air pressure switch has tripped, and there's no ignition, first check the mains supply for gas. If that's not the issue, the problem could be a malfunctioning gas valve, in which case you should replace it. Alternatively, the mechanical minimum adjustment or slow ignition adjustment on the gas valve may be set too low; try regulating these. For LPG boilers, verify that the gas valve inlet pressure isn't too high by checking the maximum pressure setting. Also, inspect the condensate disposal system for blockages and empty the condensate trap, if needed. If the problem persists and there is ignition, check if the power supply live and neutral wires are inverted and connect them correctly. The issue might also be a faulty ionization electrode, whi...

Summary

GENERAL INFORMATION

General warnings - Installation

Safety and installation guidelines for the boiler.

TECHNICAL CHARACTERISTICS

Technical data

Specifications, inputs, outputs, and dimensions of the boiler.

INSTALLATION

Installing the boiler.

Step-by-step instructions for mounting the boiler on a wall.

Water connections

Procedures for connecting water supply and return pipes to the boiler.

Condensate drain

Guidelines for installing and maintaining the condensate discharge pipe.

Gas Connection

Standards and safety guidelines for connecting the gas supply.

Electrical connections

Safety advice and procedures for electrical hookup and grounding.

Venting

Guidelines for proper boiler venting and air intake.

COMMISSIONING THE APPLIANCE

General warnings

Important safety precautions before starting the commissioning process.

Starting up the boiler

Detailed steps for the initial startup and testing of the boiler.

REGULATING THE APPLIANCE

Parameters table

Comprehensive list of configurable parameters and their functions.

Setting the parameters

Step-by-step guide on how to navigate and modify boiler parameters.

MAINTENANCE

Troubleshooting

Guide to identifying and resolving common error codes and problems.