Pentair AERMOTOR CT35 Series - User Manual

Pentair AERMOTOR CT35 Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Owner’s Record Dossier du propriétaire Registro del propietario
Pump Model
Modèle de pompe
Modelo de bomba
Pump Serial No.
Numéro de série de la pompe
La bomba número de serie
Pump Date Code
Code date de la pompe
Bomba de código de fecha
Motor H.P.
Moteur ch
Motor H.P.
Voltage
Tension
Tensión
Phase
Phase
Fase
Date of Installation
Date d’installation
Fecha de instalación
Owner
Propriétaire
Propietario
Installer
Installateur
Instalador
Installer Phone Number
Numéro de téléphone de installateur
Número de teléfono de la instalador
Installation/Operation/Parts
English ...............Pages 2-11
Installation/Fonctionnement/Pièces
Français .............Pages 12-21
Instalación/Operación/Piezas
Español ............ Paginas 22-32
Single Stage
Horsepower Range: 1/3 - 2-1/2 H.P.
60 Hz
Single and Three Phase
Installations
Seul étage
Puissance : De 1/3 à 2 1/2 chevaux
60 Hz
Installation de pompes à motor
monophasé ou triphasé
Una etapa
Fuerza: 1/3 - 2-1/2 HP 60 Hz
Instalaciones monofásicas y
trifásicas
OWNER’S MANUAL
CT35, CT45 Series Centrifugal Pump
MANUEL D’INSTALLATION ET L’OPÉRATEUR
Pompe centrifuges CT35 et CT45
MANUAL DE INSTALACIÓN Y OPERARIO
Bomba centrífugas CT35 y CT45
© 2013 Pentair Ltd. All Rights Reserved. AE926 (REV 01/16/13)
293 WRIGHT STREET, DELAVAN, WI 53115 WWW.AERMOTOR.COM
PH: 800-230-1816

Questions and Answers

  • A
    anolanAug 5, 2025
    Why Pentair AERMOTOR CT35 Water Pump not pumping enough water?
    • S
      stephaniemclaughlinAug 5, 2025
      If your Pentair Water Pump isn't delivering water to its full capacity, it could be due to the following reasons. If steel piping is used, it may be corroded or limed, causing excess friction; replace it with plastic pipe where possible, or with new steel pipe. The piping might also be too small; use larger piping.
  • S
    scott33Aug 14, 2025
    How to troubleshoot a Pentair AERMOTOR CT35 Water Pump that will not start?
    • J
      Jason RuizAug 14, 2025
      If your Pentair Water Pump motor won't run, start by ensuring the disconnect switch is on. Check for a blown fuse or tripped circuit breaker and replace or reset it. If these steps don't work, the starting switch may be defective and need replacement. Also, inspect the wires at the motor for looseness, disconnections, or incorrect wiring; refer to the wiring instructions and tighten all connections after disconnecting power. The pressure switch contacts might be dirty; disconnect power and file them with an emery board or nail file.
  • D
    Darryl NguyenAug 19, 2025
    Why does my Pentair AERMOTOR CT35 Water Pump motor overheat and shut down?
    • M
      Misty CurtisAug 19, 2025
      If the motor of your Pentair Water Pump runs hot and the overload protection activates, it could be due to several reasons. First, ensure the motor is wired correctly by referring to the wiring instructions. Low voltage could also be the problem; check with your power company and consider installing heavier wiring if the current wire size is too small. Finally, the pump might be cycling too frequently; consult the section on too frequent cycling for solutions.
  • B
    Bryan KimAug 23, 2025
    Why am I getting air spurts from my Pentair AERMOTOR CT35 Water Pump?
    • A
      Amy SantosAug 23, 2025
      If you're experiencing air spurts from your faucets when using your Pentair Water Pump, it may be picking up prime; once it has, it should pump solid water without air. The well could also be gaseous; consult the factory about installing a sleeve in the well. Another possibility is intermittent over-pumping of the well, where the water is drawn down below the foot valve; lower the foot valve if possible, or restrict the pump discharge.
  • L
    Lauren JacobsonAug 27, 2025
    How to fix a noisy Pentair AERMOTOR CT35 Water Pump?
    • M
      Mr. Kevin RichardsAug 27, 2025
      If you're experiencing mechanical or noise problems with your Pentair Water Pump, it could be due to a bent shaft and/or damaged bearings; take the motor to an authorized motor repair shop. Alternatively, the suction and/or discharge piping may not be properly supported and anchored; ensure all piping is supported to relieve strain on the pump assembly.
  • G
    galvancraigNov 1, 2025
    What to do if Pentair AERMOTOR CT35 runs but doesn't pump water?
    • J
      Joseph CooperNov 1, 2025
      If your Pentair Water Pump motor runs but no water is delivered, the cause depends on whether it's a new or existing installation. For new installations, re-prime the pump according to the instructions and check all connections on the suction line, AVC, and ejector for air leaks using soapy water or shaving cream; also, the foot valve or check valve could be leaking and may need replacement. In existing installations, check all connections on the suction line and shaft seal for air leaks, and ensure the water level is not below the suction pipe inlet; lower the suction line into the water and re-prime. If the receding water level in the well exceeds 25 feet, a deep well pump is needed. Additionally, the foot valve or strainer could be plugged and needs cleaning, the impeller might be plugg...
  • D
    davidblackNov 9, 2025
    Why does my Pentair AERMOTOR CT35 Water Pump keep cycling on and off?
    • R
      Ralph WoodNov 9, 2025
      If your Pentair Water Pump is cycling too frequently, several issues could be the cause. First, check if any faucets have been left open and close them. The impeller might be clogged, so try cleaning it. Inspect the pressure tank for waterlogging, and ensure the air volume control is working correctly, checking for any air leaks in the connections. Also, examine the pipes and foot valve for leaks and fix them. The pressure switch might need adjustment or replacement. Finally, if you have a pre-charged tank, the air charge might be too low. To fix this, disconnect power, relieve pressure, and use a tire pressure gauge to check the air pressure in the tank. If it's less than the pressure switch cut-in setting (30-50 PSI), add air until it is 2 PSI less than the cut-in setting. Check the air ...

Summary

Centrifugal Pump Owners Manual

Pump Safety Information

Key Safety Instructions

Manual contains vital safety instructions for installation, operation, and maintenance.

Electrical Safety Precautions

Precautions for safe electrical connections, including capacitor discharge and grounding.

General Operational Safety

Guidelines for safe operation, motor handling, work area, and preventing freezing.

Pump Connection Recommendations

Pump Connection Warnings

Piping and Installation Guidelines

General Piping Guidelines

Guidance on supporting, sizing, and connecting suction and discharge piping.

Suction Pipe Sizing and Connection

Instructions for increasing suction pipe diameter and proper connections.

Discharge Pipe Sizing and Connection

Guidelines for increasing discharge pipe size and recommended piping runs.

Pump Priming Procedure

Step-by-step procedure to ensure the pump is properly primed with water.

Electrical Wiring and Connections

Single Phase Motor Voltage Conversion

Instructions to change single-phase motor voltage setting from 230V to 115V.

Pump Maintenance and Repair

Old Seal Removal Procedure

Procedure for removing the old shaft seal from the pump assembly.

Floating Seat Installation

Steps for cleaning and installing the mechanical seal's floating seat.

Rotating Seal Part Installation

Procedure for installing the rotating half of the mechanical seal and impeller.

CT35 Series High Head Repair Parts

CT45 Series Medium Head Repair Parts

Pump Troubleshooting

Product Limited Warranty

Pentair AERMOTOR CT35 Series Specifications

General IconGeneral
Model SeriesCT35 Series
CategoryWater Pump
BrandPentair AERMOTOR
TypeCentrifugal Pump
Voltage115/230V
ConstructionClose-coupled
Housing MaterialCast Iron
Seal TypeMechanical Seal
PhaseSingle
Maximum Head115 ft
Outlet Size1 inch
Weight28 lbs