2 . Safety
2.1. Safety tags location
Note: Ensure that the safety tags on the device are completely legible and clean. If necessary, replace them with
new tags and put them in the same places.
2.2. Hazards
All the safety and protection instructions contained in this document must be observed in order to avoid serious or permanent
injuries, damage to property or environmental pollution.
At the same time, any other legal regulations, accident prevention and environmental protection measures, as well as any
recognized technical regulations relating to appropriate and risk-free methods of working which apply in the country and place
of use of the device must be adhered to.
Any non-observation of the safety and protection rules, as well as any existing legal and technical regulations, will result in a
risk of temporary or permanent injury, damage to property or environmental pollution.
2.2.1. Personnel
Only qualified and professional personnel, based on their training, experience and instruction as well as their knowledge of the
regulations, the safety rules and operations performed, are authorized to carry out necessary work.
2.2.2. Material
To ensure proper system operation, observe the following points :
Be careful of electrical hazards due to the 230V/12V transformer.
Do not put your fingers in the product (moving parts and residual voltage).
2.3. Hygiene and sanitation
Contact your local dealer and ask for a sanitization treatment if the treated water has an off-taste or an unusual odor.
It is strongly recommended to disinfect the system at least once a year.
3 . Description
3.1. Technical specifications
3.2. Environmental conditions
Pressure ............................................Hydrostatic: 20 bar (290.2 psi); Working: 1.38 - 8.61 bar (20.02 - 124.93 psi).
Water temperature............................2 - 38°C (35.6 - 100.4°F).
Main supply voltage fluctuations up to ±10% of the nominal voltage.
Temperature from 2°C to 50°C (35.6 - 122°F).
Relative humidity in the range 30% to 95%.
Indoor use only.