  • J
    Jeffrey BoothSep 15, 2025
    Why flow indicator on Pentair AUTOTROL 368 controller does not display service flow?
    • M
      Mary GarciaSep 15, 2025
      If the flow indicator on your Pentair Control Unit controller isn't displaying service flow, first ensure the bypass valve is not in the bypass position. If it isn't, check if the meter cable is fully inserted into the valve. If the problem persists, the meter might be clogged with debris, requiring you to remove and clean it.
  • G
    gsmithAug 25, 2025
    Why is there hard water leakage after regeneration in my Pentair AUTOTROL 368?
    • L
      Laurie GordonAug 25, 2025
      If your Pentair Control Unit is experiencing hard water leakage after regeneration, it could be due to several reasons. First, try repeating the regeneration, ensuring the correct brine dosage is set. If the issue continues, check for a leaking external bypass valve and replace it if necessary. Lastly, inspect the O-ring around the riser pipe for damage and replace if needed.
  • S
    Susan WilsonAug 25, 2025
    What to do if Pentair AUTOTROL 368 Control Unit will not draw brine?
    • C
      Cody WeeksAug 26, 2025
      If your Pentair Control Unit isn't drawing brine, it might be due to a restricted drain line, so remove the restriction. Another possibility is a plugged injector; clean the injector and screen. Also, check if any debris is preventing the valve discs from closing and remove any foreign matter.
  • C
    charlotte20Aug 26, 2025
    Why is there no conditioned water after regeneration in my Pentair AUTOTROL 368 Control Unit?
    • R
      Ronnie RossAug 27, 2025
      If your Pentair Control Unit has no conditioned water after regeneration, it could be due to a lack of brine in the brine tank. Make sure to add brine to the brine tank. Alternatively, the injector might be plugged; clean the injector and screen.
  • M
    Michael LevineSep 16, 2025
    Why Pentair AUTOTROL 368 Control Unit backwashes or purges at excessively low or high rate?
    • D
      Dennis GonzalezSep 16, 2025
      If you find your Pentair Control Unit is backwashing or purging at an excessively low or high rate, it could be due to an incorrect drain controller being used. Replace it with the correct size controller. If there is no drain line flow controller installed, install one. Also, check for any restrictions in the drain line and remove them.
  • M
    mollymezaDec 1, 2025
    What does error E3 mean on Pentair AUTOTROL 368 Control Unit?
    • J
      jeffery77Dec 1, 2025
      If your Pentair Control Unit displays "E 3", wait until the controller returns to the service position. If the camshaft is not turning during the "E 3" display, check the motor connection and the motor wire harness connection to both the motor and the controller module. Also, verify the optical sensor connection and placement, and check if the motor gear has engaged the camshaft. If everything is connected, replace components in this order: 1. Motor Assembly and optical Sensor. 2. Controller. If the camshaft is turning more than 5 minutes to find Home position, verify if the optical sensor is in place and connected to the wire and inspect for debris in the camshaft slots. If the motor continues to rotate indefinitely, replace the following components in this order: 1. Optical Sensor. 2. Co...
  • J
    james67Sep 8, 2025
    What to do if Pentair AUTOTROL 368 has flowing or dripping water at drain or salt line after recharge?
    • E
      Erik MorrisSep 8, 2025
      If there's flowing or dripping water at the drain or salt line after recharge, it could be that debris is preventing valve disc #3 or #4 from closing, so remove the debris. Alternatively, valve discs #3 or #4 might be worn and need replacement.
  • A
    Allen Sutton PhDSep 8, 2025
    How to fix Pentair Control Unit recharging at the wrong time of day?
    • J
      Jacqueline RamirezSep 9, 2025
      If the control unit is recharging at the wrong time of day, the Time of Day might be set incorrectly. Set the correct Time of Day to resolve this issue.
  • V
    vangsamanthaSep 2, 2025
    What to do if Pentair AUTOTROL 368 salt tank is overflowing?
    • R
      Rachel BrooksSep 3, 2025
      If the salt tank is overflowing, ensure all salt line connections are tight. Another possible cause is a drain line restricted with debris, so you should clean the drain control.
  • A
    Angela CookeAug 31, 2025
    What to do if Pentair AUTOTROL 368 drips water after regeneration?
    • D
      donald83Aug 31, 2025
      If you observe flowing or dripping water at the drain or brine line after regeneration in your Pentair Control Unit, it could be because debris is preventing the #3 or #4 valve disc from closing. Remove the debris. Alternatively, the #3 or #4 valve disc might be worn and need replacement.

Summary

Original Settings

Installation Settings

Details initial settings for installation including resin type, volume, and tank size.

Hydraulic Settings

Covers hydraulic parameters like injector size and refill controller number.

Electrical Settings

Specifies electrical parameters such as voltage and frequency.

Software Settings

Includes settings related to time of day, regeneration dosage, and capacity.

Maintenance Record Book

Generalities

Scope of Documentation

Defines the purpose and scope of the user guide, excluding installer information.

Product and Compliance Information

Provides manufacturer details, product model, and lists applicable norms and technical standards.

Release and Liability Notes

Details document release history and outlines Pentair's limitations of liability.

Safety

Safety Tag Location

Identifies the location of safety tags on the device and ensures their legibility.

Hazards and Personnel Safety

Addresses potential hazards, required personnel qualifications, and material safety precautions.

Hygiene and Sanitation

Recommends contact with dealer for sanitization and annual system disinfection.

Technical Specifications

Pressure and Temperature Ratings

Specifies the hydrostatic and working pressure, and the operational water temperature range.

Environmental Operating Conditions

Details acceptable environmental conditions including voltage, temperature, and humidity.

Description and Components Location

Bypassing

Programming

Basic Programming

Guides through setting the time of day, brine dosage, and regeneration intervals.

Volumetric Regeneration (606 only)

Details how to set the desired capacity for regeneration for 606 controllers.

Calendar Override Setting (606 only)

Explains setting days between regenerations for regulatory needs or flow sensor failure.

History

Operation Recommendations

Salt Usage

Recommends using EN973 certified salt pellets and avoiding rock or ice melt salts.

Sanitizing Process Impact

Notes that sanitizing may introduce chlorine, affecting resin life, requiring checks.

Manual Regeneration

Immediate Regeneration

Initiates an immediate regeneration cycle, indicated by a cascading symbol.

Delayed Regeneration

Sets a delayed regeneration to occur at the next scheduled time, indicated by a blinking regen dot.

Quick Cycle to Service Position

Allows skipping regeneration cycles to return the controller to service position.

Maintenance

Troubleshooting

Technical Support Procedure

Guides users on collecting information and contacting local dealers for technical assistance.

Pentair AUTOTROL 368 Specifications

General IconGeneral
ModelAUTOTROL 368
TypeControl Unit
Control TypeElectromechanical
ElectromechanicalYes
Power Supply120/240V AC
Voltage120/240V AC
Frequency50/60 Hz

Related product manuals