What to do if the brine tank overflows in my Pentair Control Unit?
- QqmcculloughAug 22, 2025
A brine tank overflow in your Pentair Control Unit can occur for several reasons. The brine valve (1) might be held open; try manually operating the valve stem to flush away any obstruction. An uncontrolled brine refill flow rate could also be the cause; in this case, remove the variable salt controller to clean it. Alternatively, valve (3 or 4) might not be closed during brine draw, causing a refill; flush out any foreign matter by holding the disc open and manually operating the valve stem. Finally, an air leak in the brine line could be the culprit; check all connections in the brine line for leaks.