AUTOTROL
Performa 263-268
LOGIX 740-760
INSTALLER
MANUAL
WATER PURIFICATION

Table of Contents

Questions and Answers

  • W
    William RaymondAug 18, 2025
    What to do if my Pentair AUTOTROL Performa 265 will not draw brine?
    • D
      Dr. Jennifer FitzgeraldAug 18, 2025
      If the Pentair Control Unit isn't drawing brine, several factors could be at play. First, check if the water pressure is low and adjust accordingly. A restricted drain line could also be the culprit, so remove any obstructions. Inspect the injector for blockages and clean the injector and screen. If the injector is defective, replace it along with the cap. Ensure valve disc 3 is closing properly by removing any foreign matter; if the disc is damaged, replace it. Lastly, check if the air check valve is prematurely closed; if so, momentarily put the controller into brine refill cycle. If needed, replace or repair the air check.
  • C
    crystalstrongAug 20, 2025
    Why is my Pentair AUTOTROL Performa 265 leaking hard water after regeneration?
    • M
      Melinda JenkinsAug 20, 2025
      If you're experiencing hard water leakage after regeneration with your Pentair Control Unit, it could be due to several reasons. Start by checking the brine dosage setting and repeat the regeneration process. If you have an external bypass valve, check for leaks and replace if necessary. Inspect the O-ring around the riser pipe for damage and replace if needed. Finally, verify that the brine amount and system capacity are appropriate for your system.
  • V
    Vickie WhiteAug 23, 2025
    Why am I running out of conditioned water between regenerations with my Pentair AUTOTROL Performa 265 Control Unit?
    • C
      Caitlyn Atkins DDSAug 23, 2025
      If you're running out of conditioned water between regenerations with your Pentair Control Unit, start by ensuring proper regeneration settings. Verify the brine setting is at the correct level. Also, confirm that the hardness and capacity settings are accurate. If your water hardness has increased, adjust the setting accordingly. Finally, check for any restrictions in the meter turbine rotation due to foreign matter; clean the turbine and flush with clean water, replacing the meter if necessary.
  • B
    bryancoxAug 26, 2025
    What causes brine tank overflow in a Pentair Control Unit and how to fix it?
    • A
      alyssasloanAug 26, 2025
      If your Pentair Control Unit's brine tank is overflowing, several issues might be the cause. First, check for uncontrolled brine refill flow rate. Remove the brine controller to clean the ball and seat. Also, inspect the brine line for air leaks. Check all connections in the brine line. Finally, ensure that the drain control isn't clogged with resin or other debris and clean it if necessary.
  • D
    Douglas VillanuevaAug 27, 2025
    How to stop brine tank overflow in my Pentair AUTOTROL Performa 265?
    • L
      lauren10Aug 28, 2025
      If the brine tank of your Pentair Control Unit is overflowing, it could be due to several reasons. Check if the brine valve disc 1 is being held open by foreign matter and manually operate the valve stem to flush away any obstructions. Inspect the brine line for air leaks, ensuring all connections are secure. Verify that the drain control is appropriate for the injector; a small drain control with a larger injector can reduce draw rates. Lastly, check for and clean any resin or debris clogging the drain control.
  • D
    Dawn TaylorAug 30, 2025
    Why does my Pentair AUTOTROL Performa 265 regenerate at the wrong time of day?
    • F
      floyddebbieAug 30, 2025
      If your Pentair Control Unit is regenerating at the wrong time of day, it's likely that the controller is set incorrectly. Correct the time setting according to the instructions.
  • M
    Michael JohnsonSep 1, 2025
    What to do if there is no conditioned water after regeneration in my Pentair AUTOTROL Performa 265?
    • E
      Emily MooreSep 2, 2025
      If you're not getting conditioned water after regeneration with your Pentair Control Unit, ensure there is brine in the brine tank by adding some. Also, check the injector for clogs and clean the injector and screen. If the air check valve closes prematurely, momentarily put the controller into the brine cycle. If needed, replace or repair the air check.
  • J
    Jacob JohnsonSep 4, 2025
    Why is there flowing or dripping water at the drain or brine line after regeneration in my Pentair AUTOTROL Performa 265?
    • C
      crossjohnSep 4, 2025
      If you notice water flowing or dripping at the drain or brine line after regeneration in your Pentair Control Unit, it might be because the valve stem return spring is weak; in this case, replace the spring. Another reason could be debris preventing the valve disc from closing properly, so remove any debris.
  • M
    martineztommySep 7, 2025
    What causes excessively low or high backwash/purge rates in a Pentair Control Unit?
    • D
      Dylan FisherSep 7, 2025
      If your Pentair Control Unit backwashes or purges at an excessively low or high rate, it could be due to an incorrect drain control being used; replace it with the correct size controller. Also, foreign matter affecting valve operation may be the cause; remove the drain control and clean the ball and seat.
  • K
    Keith MillerSep 9, 2025
    Why is there no water flow display on my Pentair 760 Control Unit when water is flowing?
    • B
      Brandon HenrySep 9, 2025
      If your Pentair 760 Control Unit isn't displaying water flow despite water flowing, first check if the bypass valve is in the bypass position and shift it to the non-bypass position. Then, ensure the meter probe is fully inserted into the meter housing. Lastly, check for any restrictions in the meter turbine rotation due to foreign matter; remove the meter housing, free up the turbine, and flush with clean water. If the turbine doesn't spin freely, replace the meter.

Summary

Safety

General Hazards and Personnel Safety

Covers general hazards, personnel qualifications, and safety precautions related to material and electrical components.

Description

Technical Specifications

Lists design specifications, pressure ratings, temperature limits, and flow rates for the valve.

Performance Flow Rate Characteristics

Presents a graph illustrating pressure drop versus flow rate for service and backwash cycles.

System Regeneration Cycle (8-Cycles)

Details the sequence and purpose of each step in an 8-cycle regeneration process.

System Sizing

Softener Configuration and Flow Controllers

Table mapping vessel diameter to injector and flow controller settings for softener configuration.

Installation

Piping Connection Procedures

Details how to connect the valve to the piping system, including flexible connections and electrical hookups.

Drain Line Connection Guidelines

Provides instructions for drain line connections, including tubing size, elevation, and air gap requirements.

Programming

Basic Programming Steps

Guides the user through setting up system size, time, day, regeneration, salt, and hardness parameters.

Controller Reset Procedure

Provides steps to reset the controller to its factory default settings, requiring full reprogramming.

Commissioning

Water Filling and Softener Activation

Covers initial water filling, softener activation, and manual regeneration steps for commissioning.

System Sanitization Procedures

Details the necessity and methods for disinfecting water softeners using hypochlorite or electrochlorination.

Operation

Manual Regeneration Procedures

Explains how to initiate manual regeneration, advance cycles, and cancel an ongoing regeneration process.

Maintenance

Motor and Camshaft Replacement

Procedure for replacing the motor and camshaft assembly, including necessary disconnections.

Optical Sensor and Controller Replacement

Instructions for replacing the optical sensor and the main controller module.

Troubleshooting

Logix Controller Error Codes

Lists common error codes for the Logix controller and provides causes and recovery steps.

Performa Valve Issues and Solutions

Addresses common issues with the Performa valve, such as brine tank overflow and water leakage, with troubleshooting steps.

Spare Parts

Valve Component Parts List

An illustrated list of valve components with part numbers and packaging quantities.

Pentair AUTOTROL Performa 265 Specifications