AUTOTROL
Performa 263-268
LOGIX 740-760
INSTALLER
MANUAL
WATER PURIFICATION

Table of Contents

Questions and Answers

  • E
    Eric Thomas IIAug 18, 2025
    What to do if my Pentair AUTOTROL Performa 263 will not draw brine?
    • C
      Charles GuzmanAug 18, 2025
      If the Pentair Control Unit isn't drawing brine, several factors could be at play. First, check if the water pressure is low and adjust accordingly. A restricted drain line could also be the culprit, so remove any obstructions. Inspect the injector for blockages and clean the injector and screen. If the injector is defective, replace it along with the cap. Ensure valve disc 3 is closing properly by removing any foreign matter; if the disc is damaged, replace it. Lastly, check if the air check valve is prematurely closed; if so, momentarily put the controller into brine refill cycle. If needed, replace or repair the air check.
  • J
    Jennifer MaciasAug 20, 2025
    Why is my Pentair AUTOTROL Performa 263 Control Unit leaking hard water after regeneration?
    • P
      Patricia RichmondAug 21, 2025
      If you're experiencing hard water leakage after regeneration with your Pentair Control Unit, it could be due to several reasons. Start by checking the brine dosage setting and repeat the regeneration process. If you have an external bypass valve, check for leaks and replace if necessary. Inspect the O-ring around the riser pipe for damage and replace if needed. Finally, verify that the brine amount and system capacity are appropriate for your system.
  • H
    hriceAug 23, 2025
    Why am I running out of conditioned water between regenerations with my Pentair AUTOTROL Performa 263 Control Unit?
    • T
      Timothy MullenAug 23, 2025
      If you're running out of conditioned water between regenerations with your Pentair Control Unit, start by ensuring proper regeneration settings. Verify the brine setting is at the correct level. Also, confirm that the hardness and capacity settings are accurate. If your water hardness has increased, adjust the setting accordingly. Finally, check for any restrictions in the meter turbine rotation due to foreign matter; clean the turbine and flush with clean water, replacing the meter if necessary.
  • J
    John VanceAug 26, 2025
    What causes brine tank overflow in a Pentair AUTOTROL Performa 263 and how to fix it?
    • L
      Lauren WuAug 26, 2025
      If your Pentair Control Unit's brine tank is overflowing, several issues might be the cause. First, check for uncontrolled brine refill flow rate. Remove the brine controller to clean the ball and seat. Also, inspect the brine line for air leaks. Check all connections in the brine line. Finally, ensure that the drain control isn't clogged with resin or other debris and clean it if necessary.
  • V
    Victoria MaciasAug 28, 2025
    How to stop brine tank overflow in my Pentair AUTOTROL Performa 263?
    • E
      Erica AllenAug 28, 2025
      If the brine tank of your Pentair Control Unit is overflowing, it could be due to several reasons. Check if the brine valve disc 1 is being held open by foreign matter and manually operate the valve stem to flush away any obstructions. Inspect the brine line for air leaks, ensuring all connections are secure. Verify that the drain control is appropriate for the injector; a small drain control with a larger injector can reduce draw rates. Lastly, check for and clean any resin or debris clogging the drain control.
  • B
    Billy MillerAug 30, 2025
    Why does my Pentair Control Unit regenerate at the wrong time of day?
    • E
      elizabethchaneyAug 30, 2025
      If your Pentair Control Unit is regenerating at the wrong time of day, it's likely that the controller is set incorrectly. Correct the time setting according to the instructions.
  • D
    daviscarlaSep 2, 2025
    What to do if there is no conditioned water after regeneration in my Pentair Control Unit?
    • M
      Maxwell MelendezSep 2, 2025
      If you're not getting conditioned water after regeneration with your Pentair Control Unit, ensure there is brine in the brine tank by adding some. Also, check the injector for clogs and clean the injector and screen. If the air check valve closes prematurely, momentarily put the controller into the brine cycle. If needed, replace or repair the air check.
  • M
    Marvin AyersSep 4, 2025
    Why is there flowing or dripping water at the drain or brine line after regeneration in my Pentair Control Unit?
    • D
      Darren SchwartzSep 5, 2025
      If you notice water flowing or dripping at the drain or brine line after regeneration in your Pentair Control Unit, it might be because the valve stem return spring is weak; in this case, replace the spring. Another reason could be debris preventing the valve disc from closing properly, so remove any debris.
  • S
    Stephen BakerSep 7, 2025
    What causes excessively low or high backwash/purge rates in a Pentair AUTOTROL Performa 263?
    • R
      rpayneSep 7, 2025
      If your Pentair Control Unit backwashes or purges at an excessively low or high rate, it could be due to an incorrect drain control being used; replace it with the correct size controller. Also, foreign matter affecting valve operation may be the cause; remove the drain control and clean the ball and seat.
  • K
    Kim WilkersonSep 9, 2025
    Why is there no water flow display on my Pentair 760 Control Unit when water is flowing?
    • M
      Mrs. Lisa ReedSep 9, 2025
      If your Pentair 760 Control Unit isn't displaying water flow despite water flowing, first check if the bypass valve is in the bypass position and shift it to the non-bypass position. Then, ensure the meter probe is fully inserted into the meter housing. Lastly, check for any restrictions in the meter turbine rotation due to foreign matter; remove the meter housing, free up the turbine, and flush with clean water. If the turbine doesn't spin freely, replace the meter.

Summary

Safety

Safety Pictograms Definition

Explains the meaning of safety symbols used in the manual.

Safety Tags Location

Identifies the location of safety labels on the product.

Hazards

General warnings about potential risks during operation.

Personnel

Material

Description

Technical Specifications

Details on valve body, flow rates, connections, and electrical ratings.

Performance Flow Rate Characteristics

Description and Components Location

System Regeneration Cycle (8-cycles operation)

Filter Cycle (4-cycles operation)

System Sizing

Injector flow rates (tables)

Installation

Safety notices for installation

General safety warnings to observe before installation.

Installation environment

Guidelines for general, electrical, mechanical, and outdoor environments.

Integration constraints

Valve connection to piping

Top-mounted valve installation

Specifics on mounting the valve on top of the tank.

Connections (electrical)

Bypassing

Drain line connection

Brine line connection (Performa 268 - Softener configuration only)

Basic programming

Program system size

Time setting and winter time - summer time change

Day of week

Regeneration time

Days to regenerate (740 time-clock controller only)

Calendar override (760 on-demand controller only)

Amount of brine used per regeneration

Estimated capacity

Hardness (760 on-demand controller only)

Diagnostic

Resetting the controller

Commissioning

Water filling, draining and waterproofness inspection

Initial steps for filling the tank and checking for leaks.

Operation

To advance regeneration cycles

To cancel a regeneration

Maintenance

Cleaning the injector screen

Cleaning the backwash controller

Disassembling valve cover

Motor and camshaft replacement

Optical sensor and controller replacement

Turbine cleaning or replacement

Top plate, flapper spring and flappers replacement

Troubleshooting

Performa Valve

Pentair AUTOTROL Performa 263 Specifications

General IconGeneral
BrandPentair
ModelAUTOTROL Performa 263
CategoryControl Unit
LanguageEnglish