12
* AUTOJET 60/50, AUTOJET 70/50, AUTOMAX 80/48, AUTOMAX 120/60
If the problem persists despite the recommended corrective actions, contact the Customer Assistance Service.
PROBLEM POSSIBLE CAUSE REMEDY
THE PUMP IS NOT RUNNING
1) No water. Red LED light on (FAILURE)*. Identify the cause, and
then restart by pressing the RESTART button.
2) Pump stalled. Identify the cause and unblock the pump.
3) No current. Check that power is present and that the plug has been
inserted properly. The Green LED light (power On) is off*.
4) FLUSSCONTROLL* is faulty. Contact the Customer Assistance Service.
THE PUMP DOES NOT STOP
1) Reset button blocked. Inspect the pump and clean it if necessary.
2) The pump sucks air. See point 4.
3) FLUSSCONTROLL* faulty. Contact the Customer Assistance Service.
THE ELECTROPUMP DOES NOT
PUMP WATER,
THE MOTOR DOES NOT RUN
1) No power. Check that power is present and that the plug has been
inserted properly. The Green LED light (power On) is off*.
2) Motor protection tripped. Identify the cause, and then restart by pressing the
RESTART* button. Wait until the system has cooled
down if the thermoregulator has intervened.
3) Defective condenser. Contact the Customer Assistance Service.
4) Shaft blocked. Identify what caused the block:
a) Make sure that the power supply cable has been
unplugged
b) Remove the fan cover
c) Try to unblock the shaft by turning the cooling fan.
Contact customer services if the problem persits
THE MOTOR RUNS BUT THE ELECTROPUMP
DOES NOT PUMP LIQUID
1) The pump is sucking air. Check to ensure that joints are leak proof.
Check that liquid levels have not decreased beneath
the foot valve.
Check to ensure that the foot valve is unblocked and
leak proof.
THE ELECTROPUMP STOPS
AFTER RUNNING FOR A SHORT PERIOD
OF TIME BECAUSE ONE OF THE THERMAL
MOTOR CIRCUIT BREAKER TRIPS
1) The power supply does not comply with
the data on the nameplate.
Check the voltage on the power supply cable leads.
2) A solid object is blocking the impellers. Contact customer services.
MAINTENANCE AND TROUBLESHOOTING
CHAPTER 7
•
EN
Make sure the machine is disconnected from electric power supply, before performing maintenance operation.
DANGER - ELECTRIC SHOCK RISK