ELECTRIC CONNECTION
CHAPTER 4
Ensure tension and frequency of pump (read motor plate) and supply network are same.
WARNING
Installer must make sure that electric current network has ground wire conforming to current laws.
Make sure that electric current network is provided with a high-sensitivity circuit-breaker
∆=30 mA (DIN VDE 0100T739).
DANGER - ELECTRIC SHOCK RISK
DANGER - ELECTRIC SHOCK RISK
CONNECTIONS DIAGRAM (See diagrams Pict.2) :
1. START (green)
2. RUN (red)
3. COMMON (black)
4. CAPACITOR
A. Single phase manual pump
5. SUPPLY CORD
6. GROMMET
7. PLUG
8. YELLOW-GREEN
B. Single phase automatic pump
9. WHITE
10. LIGHT BLUE <LINE>
11. BROWN <LINE>
12. FLOAT SWITCH
BIOX® range pumps have a built-in thermal overload with automatic reset. Further protections are not required.
BIOX® range three phase pumps can be protected by using a magneto-thermic motor protector or a contactor with thermal relay;
in both cases they have to be rated conforming to nominal power showed on motor plate.
Eventual electric float switch must be connected to auxiliary connector buckles.
Water head and delivery are terribly effected by wrong rotation of shaft of pump motor. Clock wise rotation is correct (upside view of
pump). When startin the pump motor will ungergo an anti-clock wise back-kick.
In this case test is positive; on contrary case, please disconnect pump from network and inverse two phases.
Single phase pumps are equipped with double ground contact plug at top end of supply cord ; in this case grounding is done when
plugging in.
In this case the ground wire (yellow-green cable) of supply cord must be connected to ground wire of electric current network.
Ensure connection to electric current network by using an omnipolar-sectionned magneto thermic circuit-breaker.
This will ensure effective disconnection from electric current network.
OVERLOAD PROTECTION
ROTATION DIRECTION TESTING THREE PHASE PUMPS
SINGLE PHASE VERSION
THREE PHASE VERSION
C. Three phase pump

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pentair NOCCHI BIOX Series and is the answer not in the manual?

Pentair NOCCHI BIOX Series Specifications

General IconGeneral
BrandPentair
ModelNOCCHI BIOX Series
CategoryWater Pump
LanguageEnglish

Related product manuals