30
11 TECHNICAL SPECIFICATION
Supply voltage 230VAC, +10%, –15%, 50/60 Hz
Power consumption, average 4 VA
Main power switch 2-pole
Relay output 230V, max. 13A
Ambient temperature – operation 0 +40°C
Ambient temperature – transport –20 +50°C
Protection class IP 21
Terminals Max. 2,5 mm²
Floor sensor with 3 m cable NTC, 10KΩ / 25°C
Maximum length of floor sensor
cable
100 m, 2 x 1,5 mm² (230VAC cable
type)
Dimension with frame (Figure1) H 82 x W 82 x D 57 mm
Colour Polar white RAL 9010
Display LCD with blue backlight
Control modes Floor sensor (+5 +35°C)
Room sensor (+5 +40°C)
Room sensor with floor sensor
as a limiter
Room temperature control
accuracy EN15500
CA = 0,7K eu.bac certified
Floor sensing hysteresis 0,5°C (Factory settings adjustable
between 0,2-2,0°C)
Accuracy – floor/room sensor ± 0,5°C at 25°C
Program Selection 4 programs:
- Comfort (Fixed Program)
- EcoHome (Fully Customizable)
- EcoOffice (Fully Customizable)
- OFF
Back-up for set values In non-volatile memory
Back-up for time and date 24 hours
Optional external set back feature 6 external set-back signals
Table 8