3.2 MOUNTING THE FLOOR SENSOR
The floor sensor should be installed in a separate
flexible conduit for easy replacement and in order
to avoid signal disturbance resulting in a possible
malfunction of the thermostat. For best control
performance, position the floor sensor between two
heating cables as close as possible to the top floor
surface.
Do not position the floor sensor tip closer than 3 cm
to the heating cable.
500 mm
Figure 5
Remark: The floor sensor cable can be extended to
100 m with a separate standard installation cable
2 x 1.5 mm
2
(230VAC).