85
6 - SPECIFICHE
Prestazioni
Condizioni operative minime e massime
Condizioni Minimo Massimo
Pressione di ingresso 2.76 bar (40 psi) 5.52 bar (80 psi)
Temperatura in ingresso 4.44°C (40°F) 37.78°C (100°F)
TDS in ingresso 50 mg/L 2,000 mg/L
Durezza in ingresso 0 mg/L (0 grain) 171 mg/L (10 grain)
Cloro in ingresso 0 mg/L 1.0 mg/L
Ferro in ingresso 0 mg/L 0.1 mg/L
Manganese in ingresso 0 mg/L 0.05 mg/L
pH in ingresso 4 10
Torbidità in ingresso 0 1 NTU
Dimensioni
(243.9)
9.6
(508.9)
20.03
(383.5)
15.10
(242.5)
9.55
(89.8)
3.53
(140)
5.51
(84.3)
3.32
(130.4)
5.13
(59.4)
2.34
(114.3)
4.50
(25.4)
1.0
(50.8)
2.0
(261)
10.27
(268.2)
10.56
I
T
A
L
I
A
N
O