PUMP CONNECTION & INSTALLATION INSTRUCTIONS (Continued)
2.8 Insert the wire leads into Plug (Cable Adapter) connectors and use a 5/64" Allen Wrench to tighten the set screws (Fig. 6).
Either wire can go into either plug hole. Pump performance will be the same.
2.9 Slide the Inner Cable Boot (B) over the plug until it is flush with the first step on the collar (Fig. 7).
2.10 Wipe the grease from the surface of the Inner Cable Boot (B) and Cable (A).
2.11 Tape end of Inner Cable Boot (B) tightly to the Cable (A). Tape 4 in. (10 cm) past the Inner Cable Boot (B) onto the Cable (A).
Note: This taped area allows the Outer Cable Boot (C) to slide freely over the Inner Cable Boot.
DO NOT REMOVE THE TAPE.
2.12 Lubricate the outer surface of the Inner Cable Boot (B) and tape with supplied O-Ring grease.
2.13 Slide the Outer Cable Boot (C) over the Inner Cable Boot (B) until it is flush with the second step on the collar (Fig. 7).
2.14 Push the Plug (Cable Adapter) into the Receptacle (Cable Adapter) until the collar is seated flush.
2.15 Push the Nut (D) over the Plug (Cable Adapter) and then finger tighten the nut.
NOTE: Before continuing, operate the pump to check all electrical connections. Refer to Technical Specifications (Pg. 14).
If the pump does not operate, refer to TROUBLESHOOTING (Page 8).
3. Install the 6 inch hose and fitting (1/2" NPT-M x 1/2" BARB) (Fig. 8)
3.1 Press the fitting into the 6 in. hose, slide a clamp on the hose and over the fitting and tighten the clamp securely.
3.2 Slide another clamp on the 6 in. hose and slide the assembly over the barbed fitting on the
pump and tighten the clamp securely.
Note: Select the proper adapter hose and accessories for the pump.
USE OF DISCHARGE PIPE LARGER THAN 3/4" IS NOT RECOMMENDED..
Use 150 P.S.I. Min. [10 bar] working pressure rated 1/2 in. [13 mm] Inner
Diameter smooth bore hose. Use included All-Stainless Steel hose clamps.
4. Hook-up Safety Line (Sling) (Fig. 8)
CAUTION: Safety line (Sling) should be Corrosion-resistant.
4.1 Insert safety line (Part not included) through lift plate holes.
4.2 Fasten line with appropriate connection approximately 1-2 ft [25-50 cm] above the pump.
5. Band the Hose, Safety Line, and Electrical Cable (Fig. 9)
5.1 Tie the drop lines together using tie wrap every 6ft. (1.8 m).
This banding will prevent damage to the lines during Installation and Removal of pump.
6. Install Pump (Fig. 9).