9
II. PUMP REMOVAL AND DISASSEMBLY
Warning: Make sure all electrical power is off and the Hose (Pipe) is not under pressure.
Warning: Canister may be pressurized. Disassemble the pump in proper order.
Follow the directions carefully.
Note: Keep all of the parts clean after disassembly. Upper Housing Assembly contains small parts.
Be careful not to lose parts after removing Upper Housing (N) in step 9.
1. Turn Off All Electrical Power
2. Remove the Pump from the Well
NOTE: To prevent damage to the Electrical Connection
DO NOT PULL ON THE ELECTRICAL CORD OR USE IT TO
LIFT THE PUMP OUT OF THE WELL.
3. Disconnect the Hose
3.1 Remove the Hose clamp.
3.2 Pull and twist the hose to remove it from the fitting.
4. Unplug the Cable Adapter Assembly (Fig 10)
4.1 Remove the Nut (D) unscrewing it counterclockwise and pull
the plug up.
5. Remove the Lift Plate (F) (Fig. 10)
5.1 Use a #2 Phillips Screwdriver to remove 6 screws (E).
5.2 Pull up the Lift Plate (F).
Note: Be sure to put the O-Rings (I) back on the Lift Plate
Posts (F).
(Fig. 11, View B) before continuing to Step 6.
6. Remove the Filter Screen (M) for Cleaning
6.1 Slide the Filter Screen (M) out of the Canister (U).
6. Remove the Outlet Fitting (G) (Fig. 10)
6.1 Pull the Fitting (G) straight out from the Upper Housing (N).
7. Remove the Receptacle (Cable Adapter) (J) (Fig. 10)
Note: DO NOT PULL ON THE ELECTRICAL PRONGS.
7.1 Using pliers, carefully pull up on the shoulder of the
Receptacle (Cable Adapter) (J).
7.2 Pull Cable Adapter (J) completely out of the Upper Housing (N).
7.3 Use a 5/64" Allen Wrench to loosen the 2 screws (K) holding
the motor leads and disconnect the Receptacle
(Cable Adapter) (J).
8. Remove the Canister (U) (Fig. 11)
8.1 Use a 3/16" Allen Wrench to remove the 3 screws (V).
8.2 Holding the Upper Housing (N) and the Canister (U), twist and
pull the Assembly apart.