EasyManua.ls Logo

Pentair ULTRATEMP 70 - Wiring Diagram - Three Phase; Three Phase Wiring Diagram

Pentair ULTRATEMP 70
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ULTRATEMP
®
Heat Pump Installation and Users Guide
11
ENGLISH
ESPAÑOL
FRANÇAIS
Wiring Diagram – (Three Phase – 60Hz)
Compressor
T1 T3
T2
24 VAC
C
O
M
P
R
E
S
S
O
R
F
A
N
L
O
W
P
R
E
S
H
I
P
R
E
S
R
E
V
E
R
S
I
N
G
V
A
L
V
E
F
L
O
W
10K ohm
Thermistors
1
2
3
4
5
6
Fan
Water Pres Sw
Lo Ref Pres Sw
Hi Ref Pres Sw
TBL
TBR
Optional
Reversing Valve
1
2
3
4
5
6
7
8
WHITE
WHITE
BLUE
YELLOW
BLUE
YELLOW
WHITE
WHITE
BLACK
RED
BLACK
RED
RED
RED
BLACK
BLACK
RED
WHITE
GREEN
COM
SPA
POOL
INPUT
SWITCHES
J9
WTR
TEMP
J4
DEF
TEMP
J5
3-WIRE
REMOTE
TERM.
PWR
J7
RS-485
J8
INTELLITOUCH
®
CONTROL SYSTEM
CONNECTION
BLACK
OUTPUTS
J3
BLACK
PURPLE
BLACK
BLACK
Capacitor
Transformer
208V
240V
24 VAC
COM
Filter Pump
Contactor
Compressor
Contactor
Fan
Relay
NO
NC
PURPLE
RED
BLACK
BLUE
BLUE
WHITE
PURPLE
ORANGE
BLACK
YELLOW/BLUE
TAN
WHITE
BROWN
BROWN
PINK
PURPLE
BROWN
BROWN
RED
BLACK
Incoming 230 VAC 60 Hz
3Phase Power Connection
GREEN
PINK
TAN
ORANGE
BLACK
T1
T2
T3
L2
L3
L1
L1
L2 L3
Y-Out
CY
Phase Prot ection Devi ce
GRAY
ORANGE/BLACK
RED
YELLOW
GREEN
YELLOW/BLUE
RED
GRAY
THERM
1
THERM
2
GREEN
C
Note: If red LED is on, swap any two phases.
LABEL P/N 474022 REV. D
HEAT PUMP CONTROL BOARD

Table of Contents

Related product manuals